4.3 Check the TK Tape Drive Load Path
In console mode, you can use the Z command to "attach" to
the TK controller on the VAXBI. Run a ROM-based test to
verify that the load path works properly. Return the console
to the boot processor.
Example 4–1:
TK ROM-Based Diagnostic
!
>>> SHOW CONFIGURATION
Type
Rev
1+
KA64A
(8082)
0007
2+
KA64A
(8082)
0007
3+
KA64A
(8082)
0007
4+
KA64A
(8082)
0007
7+
MS65A
(4001)
0084
8+
MS65A
(4001)
0084
9+
MS65A
(4001)
0084
A+
MS65A
(4001)
0084
D+
DEMNA
(0C03)
0600
E+
DWMBB/A
(2002)
0001
"
XBI E
1+
DWMBB/B
(2002)
0001
2+
CIBCA
(0108)
41C1
4+
TBK70
(410B)
0307
"
#
>>> Z/BI:4 E
?33 Z connection successfully started.
$
T/R
%
RBD4> D2/TR/T=6/C
;T1035_TK
1.00
;T06
;
P
&
6
410B 00000001
;00000000 00000000 00000000 00000000 00000000 00000000 00000000
'
RBD4> QUIT
(
^P
?31 Z connection terminated by ^P
>>>
4–12
VAX 6000: Installing the
VAXBI Option