SHOW
2–85
HSZ40 Array Controller
CLI Reference Manual
To show a complete listing of the mirrorset named MIRR1:
CLI> SHOW MIRR1
Name Storageset Uses Used by
------------------------------------------------------------
MIRR1 mirrorset DISK130 D202
Switches:
NOPOLICY (for replacement)
COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 2, 1 member present
State:
DISK130 (member 0) is NORMAL
Size: 4109470 blocks
To show the full information for a controller:
CLI> SHOW THIS_CONTROLLER FULL
Controller:
HSZ40-CX (C) ZG60300054 Firmware V31Z-0, Hardware 0000
Not configured for dual-redundancy
SCSI address 6
Time: NOT SET
Host port:
SCSI target(s) (4, 5), Preferred target(s) (5)
TRANSFER_RATE_REQUESTED = ASYNCHRONOUS
Cache:
No cache
Host Functionality Mode = A
Licensing information:
RAID (RAID Option) is ENABLED, license key is VALID
WBCA (Writeback Cache Option) is ENABLED, license key is VALID
MIRR (Disk Mirroring Option) is ENABLED, license key is VALID
Extended information:
Terminal speed 19200 baud, eight bit, no parity, 1 stop bit
Operation control: 00000005 Security state code: 24968
Configuration backup disabled