
2–84
SHOW
To show a full listing of devices attached to the controller:
CLI> SHOW DEVICES FULL
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
DISK100 disk 1 0 0 D500
DEC RZ28 (C) DEC 435E
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 10MHZ (synchronous 10 MB/SEC negotiated)
Size: 4109470 blocks
DISK120 disk 1 2 0 S0
DEC RZ28 (C) DEC 435E
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 10MHZ (synchronous 10 MB/SEC negotiated)
Size: 4109470 blocks
DISK140 disk 1 4 0 S0
DEC RZ28M (C) DEC 0616
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 10MHZ (synchronous 10 MB/SEC negotiated)
Size: 4109470 blocks
DISK200 disk 2 0 0 D501
DEC RZ28 (C) DEC 435E
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 10MHZ (synchronous 10 MB/SEC negotiated)
Size: 4109470 blocks
DISK220 disk 2 2 0 S0
DEC RZ28B (C) DEC 0006
Switches:
NOTRANSPORTABLE
TRANSFER_RATE_REQUESTED = 10MHZ (synchronous 10 MB/SEC negotiated)
Size: 4109470 blocks
Summary of Contents for HSZ40
Page 6: ......
Page 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Page 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Page 112: ......