background image

1

FP-3710T Series 

Installation Guide

Package Contents

„

 FP unit (1) 

„

 Installation Guide (1) (this manual)

„

 Warning/Caution Information (1)

„

 Installation Gasket (1) 

 

(attached to the FP unit)

„

 Installation Fasteners 

 

(4/set, 2sets)

„

 USB Cable Clamp (1)

„

Power Plug (1) 

  (attached to the FP unit)

This unit has been carefully packed, 
with special attention to quality. 
However, should you find anything 
damaged or missing, please contact 
your local FP distributor immediately.

Required software/Reference 
manual

The FP-3710T Series unit needs the 
following software for operation. As 
FP user manual, provided by PDF 
media, describes its details, 
download the manual below and get 
the further information. Visit Pro-face 
website below and get both software 
and reference manual. (URL:http://
www.pro-face.com/otasuke/)
• Software

: Mouse Emulation 

Software

• Manual

: FP3000 Series 

User Manual 

Installation prerequisites for 
standards

For the detailed certification's 
information, refer to the Pro-face 
Home page. 

<Cautions>
Be aware of the following items 
when building the FP into an end-
use product:

For indoor use only.

This unit should be installed in the 

front face of a metal panel.

If this unit is installed so as to cool 

itself naturally, be sure to install it in a 
vertical panel. Also, be sure that the 
FP unit is mounted at least 100 mm 
away from any adjacent structures or 
equipment. If these requirements are 
not met, the heat generated by the 
FP unit’s internal components may 
cause the unit to fail to meet UL/c-UL 
standard.

For use on a flat surface of a Type 

4X (Indoor Use Only) and/or Type 12 
Enclosure.

Type 4X (Indoor Use Only) and/or 

12 Enclosure, when the hatch for 
Front USB Port is secured by screw. 

 

Type 1 Enclosure, when the hatch for 
Front USB Port is open.(FP3710-
T42-U, FP3710-T42-24V-U only)

Receivable signals are only from 

isolated secondary source.

Caution

Be sure to read the “Warning/Caution 
Information” on the attached sheet 
before using the product.

AC type

DC type

Summary of Contents for FP-3710T Series

Page 1: ...es for standards For the detailed certification s information refer to the Pro face Home page Cautions Be aware of the following items when building the FP into an end use product For indoor use only This unit should be installed in the front face of a metal panel If this unit is installed so as to cool itself naturally be sure to install it in a vertical panel Also be sure that the FP unit is mou...

Page 2: ...Nonincendive Circuit Parameters Front USB I F Voc 5 0 V Isc 1 25 A Ca 10 µF La 16 µH 2 Selected Associated Nonincendive Field Wiring Apparatus shall satisfy the following 3 If the electrical parameters of the cable are unknown the following values may be used Capacitance 60pF ft Inductive 0 20 µH ft 4 Nonincendive Field Wiring must be installed in accordance with article 501 10 B of the National E...

Page 3: ...ace F DVI D Interface Connector Connector for DVI D interface G Serial Connector Connector for serial RS 232C interface Used for sending touch panel data to the host H USB Connector Type B Connector for USB interface Used for sending touch panel data to the host or used as an upstream port for USB HUB I Front LED Used to indicate the condition of the power supply a backlight burnout or image signa...

Page 4: ... displayed SW2 Dimensions Dip Switches and Slide Switch Switch Setting SW1 1 Reserved Always OFF SW1 5 Reserved Always OFF SW1 2 Display Hide the OSD SW1 6 Reserved Always OFF SW1 3 Reserved Always OFF SW1 7 Reserved Always OFF SW1 4 Reserved Always OFF SW1 8 Reserved Always OFF Switch Setting Slide Switch is used to switch the data input output command control method on the touch panel between US...

Page 5: ...een Resolution Expansion H Horizontal V Vertical Display Resolution 640 400 24 827 56 000 21 053 1 6 H 1 92 V 1024 768 640 400 31 469 70 000 25 175 640 480 31 469 59 992 25 175 1 6 640 480 35 000 66 667 30 240 640 480 37 500 75 000 31 500 720 400 1 1 When you use this resolution set ON for 720 400 Mode in the OSD On Screen Display System Settings 31 469 70 000 28 320 1 42 H 1 92 V 800 600 37 879 6...

Page 6: ... 56 000 21 053 1 6 H 1 92 V 1024 768 640 400 31 469 70 000 25 175 640 480 31 469 59 992 25 175 1 6 640 480 35 000 66 667 30 240 640 480 37 500 75 000 31 500 720 400 1 1 When you use this resolution set ON for 720 400 Mode in the OSD On Screen Display System Settings 31 469 70 000 28 320 1 42 H 1 92 V 800 600 37 879 60 317 40 000 1 28 800 600 46 875 75 000 49 500 1024 768 48 363 60 004 65 000 1 0 1...

Page 7: ...ue to the possibility of noise interfering with the FP unit s operation Only when the FP 3710T series is connected with PS 2000B or PL 3000B Revision B or more FP DV01 100 can be used Please turn on PS 2000B s internal dipswitch 4 when you use FP DV01 100 with PS 2000B The resolution that can be displayed is 1024 x 768 only XGA Please turn off dipswitch 4 when you use FP DV01 50 Please set PL 3000...

Page 8: ...able other than the specified USB cable is used product performance cannot be guaranteed due to the possibility of noise interfering with the FP unit s operation Installation FP X Y Panel thickness FP 3710T Series 383 5 15 10 282 5 11 12 1 6 0 06 to 10 0 0 39 Installation gasket must be used even though it is not necessary for its environment For installation refer to the FP3000 Series User Manual...

Page 9: ...force can damage the FP unit s case The necessary torque is 0 5 N m 4 4 lb in Wiring Item Specification DC TYPE AC TYPE Power Supply Rated Voltage DC24V AC100 to 240V Allowable Voltage DC19 2 to 28 8V AC85 to 264V Rated Frequency 50 60HZ Allowable Frequency Range 40 72Hz Allowable Voltage Drop 5ms or less 1 cycle Max Voltage drop interval must be 1s or more Current Consumption 40W or less AC100V 1...

Page 10: ...ese screws is 0 5 to 0 6 N m 4 4 to 5 3 lb in To prevent the possibility of a termi nal short use a pin terminal that has an insulating sleeve Item Specification Surrounding Air Temperature 0 to 50ºC The panel should not incline more than 30º Storage Temperature 20 to 60ºC Ambient Humidity 10 to 90 RH No condensation Wet bulb temperature 39ºC max Storage Humidity Air Purity Dust 0 1mg m3 Max No el...

Page 11: ...place 4 After inserting all three pins insert the Power Plug into the Power Con nector at FP Fix the plug with two 2 minus screws Confirm that all wires are connected correctly The torque required to tighten these screws is 0 5 to 0 6 N m 4 4 to 5 3 lb in To prevent the possibility of a termi nal short use a pin terminal that has an insulating sleeve USB Cable Clamp Attachment Procedure Installati...

Page 12: ...utput signal lines Connect a surge absorber to handle power surges To reduce noise make the power cord as short as possible The temperature rating of field installed conductors 75 ºC only Must be used with a Class2 Power Supply FP3710 T42 24V U When attaching a wire to the FP unit s rear face FG terminal on the AC Connector be sure to create an exclusive ground Use a grounding resistance of 100Ω a...

Page 13: ...lection SELECT Selects icons or items SAVE Saves the current value and quits the OSD EXIT Quits the OSD To start the OSD and enter OSD mode press the three corners of the touch panel in turn upper left upper right and lower right within 5 seconds In OSD mode the setting screen is displayed in the center of the screen In this mode the touch panel cannot be used to export data to external devices un...

Page 14: ...ion of the change item Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu Screen Settings H Position V Position H size Phase Display Clock Contrast R Contrast G Contrast B Contrast Brightness Color Settings Adjustment button Selection of the change item Adjustment button Applies the setting and then returns to the top menu Cancels the setting ...

Page 15: ... or a steady orange Touch operation will be disabled when the backlight burns out which prevents the FP from sending input signals to the PLC BL Alarm Normally the FP unit detects a backlight burnout by monitoring the backlight s current flow however the FP may fail to detect this condition depending on the type of backlight problem Auto off Disp Selection of the change item System Settings Enable...

Page 16: ...eturns to the top menu Input Source Auto Adjust Analog RGB only Applies the setting and then returns to the top menu Cancels the setting and then returns to the top menu Resets all the settings and then returns to the top menu Cancels the setting and then returns to the top menu All Reset Note Regardless of the above clause Digital Electronics Corporation shall not be held responsible for any dama...

Reviews: