background image

R4000 Series CPU Upgrade

Part Number: EK-4MMIN-UP.A01                        

DECstation 5000
Model 150

MLO-010159

Summary of Contents for DECstation 5000 Model 200

Page 1: ...R4000 Series CPU Upgrade Part Number EK 4MMIN UP A01 DECstation 5000 Model 150 MLO 010159...

Page 2: ...here Switch 1 in the off position and Switch 2 in the on position Note Save all the packaging you will need it for returning your R3000 CPU Check the Shipment Contents CPU upgrade module Labels Produ...

Page 3: ...system more etc motd If you do not have ULTRIX and UWS Version 4 3A or later you must upgrade your software before you continue See the Guide to Installing ULTRIX for information on upgrading your sy...

Page 4: ...lled a new version of software enter the printenv command at the console prompt to show the location of your software for example printenv 3 rz0 vmunix a In this example the software is located on a h...

Page 5: ...tlet 2 Unscrew the captive screw on the back of your system unit cover 3 Slide the cover a few inches towards the front 4 Lift the cover off and set it aside Remove the System Unit Cover 0 1 2 2 PMAG...

Page 6: ...the side of the system box to ground it Caution Do not touch anything inside the system unit until you have the antistatic wrist attached Failure to use the antistatic wrist strap can result in damage...

Page 7: ...of the mounting posts to un lock them 2 Pry the module up with your fingers 3 Set the R3000 CPU module aside Remove the R3000 CPU Module Mounting posts MLO 010162 CPU module connector Heat sinks CPU...

Page 8: ...e board with your fingers until each mounting post locks and the CPU module connector is seated in the base module connector Caution Do not push on the heat sink 3 Remove your wrist strap Install the...

Page 9: ...allion tabs and pop the medallion out 3 Choose the correct system medallion Workstation DECstation 5000 Model 150 Server DECsystem 5000 Model 150 4 Snap in the new medallion and turn the cover right s...

Page 10: ...lace the system unit cover and tighten the captive screw Replace the System Unit Cover 0 1 2 2 PMAG C V 100 120 A 3 0 V 220 240 A 1 7 V 100 120 2 20 240 A 7 9 4 2 Hz 50 60 W 359 MLO 010232 Captive Scr...

Page 11: ...e console prompt displays on the screen 3 Using the information from the printenv command display you re corded earlier reboot the system soft ware as in the following example setenv boot 3 rz0 vmunix...

Page 12: ...mail it to Digital Equipment Corporation Call your Digital service representative to update your hardware service contract Return R3000 CPU to Digital Digital Equipment Corporation 1993 All rights res...