Table 4–3 (Cont.) DECbridge 90 Messages
Error Message
Description
Hub h slot s not a repeater
The device does not use the same management
protocol as the DECrepeater 90 series repeaters.
The device ports, if any, cannot be managed by the
DECbridge 90 unit.
Hub h slot s unrecognized type
The repeater type in hub h slot s is not known to
the DECbridge 90. The repeater ports can still be
managed with the DECbridge 90.
No repeater responds
There is no repeater installed in the requested hub
slots, or the repeater is not functioning.
No such port
The bridge port number provided to the SHOW PORT
command was invalid. Valid numbers are 1 and 2.
Password too long - not changed
A password longer than 16 characters was given to the
DEFINE BRIDGE PASSWORD command.
Port number [[hub,]slot,]port
One of the parameters provided to a SET PORT or
DEFINE PORT command was not a valid hub, slot, or
port number.
Station address number
[first [,last] ] in range 1-200
One or more parameters provided to the SHOW
ADDRESS command was invalid. The valid range is 1
to 200.
Unsupported by this hardware
revision
This occurs when you attempt to execute a SET or
DEFINE BRIDGE FLOOD command on a bridge with
a firmware revision of 1 (DECbridge 90 V1.4) but
have loaded V2.5 or a later version flash EPROM. The
old hardware revision does not support flood mode.
These version numbers appear in the MOP console
connection banner.
???
A command or parameter was not recognized. Enter ?
to display valid commands.
180501
A loopback diagnostic has run and passed on the
backbone port. If the backbone port is not receiving
any messages, this diagnostic is run every 10 minutes.
180201
A loopback diagnostic has run and passed on the work
group port. If the work group port is not receiving any
messages, this diagnostic is run every 10 minutes.
1805:00-00-00-00
01
A loopback diagnostic has run and failed on the
backbone port. The diagnostic is tried every 5 seconds
until the test passes.
(continued on next page)
Managing the DECrepeater 90FA 4–19