![Digital Equipment DEChub ONE Repeater 900SL Installation Manual Download Page 11](http://html1.mh-extra.com/html/digital-equipment/dechub-one-repeater-900sl/dechub-one-repeater-900sl_installation-manual_2498812011.webp)
Repeater Cabling
Table 1 lists the maximum distance between two adjacent repeaters, and between a repeater and
a station. You can use UTP level 3 cable to extend lobe length, but do not use it as a trunk cable.
Table 1 Maximum Cable Length between Active Units
1
1
All distances include patch cables and hub connections.
Table 2 shows the industry guideline for cable length between a repeater and a passive MAU.
Although cable lengths in excess of these distances are physically possible with a DECrepeater
900TL, Digital recommends that you keep cable lengths within the maximums found in the industry
guideline to allow for future network expansion and upgrade.
Table 2 Industry Cable Length Guideline between a Repeater and a Passive MAU
1
1
All distances include patch cables and hub connections.
DEChub 900 MultiSwitch Configuration
Multiple Hubs
A repeater is needed in each DEChub 900 MultiSwitch to connect hubs in a multiple hub network.
UTP
Speed
Level 3
Level 5
4 Mb/s
100 m (327 ft)
100 m (327 ft)
16 Mb/s
65 m (213 ft)
100 m (327 ft)
UTP
Speed
Level 3
Level 5
4 Mb/s
300 m (983 ft)
400 m (1311 ft)
16 Mb/s
130 m (426 ft)
200 m (655 ft)