EISA Configuration Utility (ECU)
EISA Configuration Utility (ECU)
Running the
ECU
To configure the Ethernet controller within the system or to
change the configuration settings, you must run the ECU. See
the DECpc AXP 150 and DEC 2000 Model 300 AXP Customer
Technical Information manual for information on running the
ECU.
Changing the
Configuration
You can use the ECU to change the configuration of the SCSI
adapter. Table 2–1 shows the functions and the corresponding
choice of settings that are available for the AHA-1742A SCSI
adapter.
Table 2–1 Configuration Settings
Function
Choice of Settings
Host Adapter Interface
Enhanced mode only
Host Adapter BIOS
BIOS Base Address CC000H
BIOS Base Address D0000H
BIOS Base Address D4000H
BIOS Base Address D8000H
BIOS Base Address DC000H
BIOS Base Address E0000H
BIOS Base Address E4000H
BIOS Base Address E8000H
BIOS Base Address EC000H
BIOS Base Address C8000H
BIOS Disabled
Host Adapter SCSI ID
Device ID 7
Device ID 6
Device ID 5
Device ID 4
Device ID 3
Device ID 2
Device ID 1
Device ID 0
SCSI Bus Reset at Power-on
Enable SCSI Bus Reset
Disable SCSI Bus Reset
2–2 Configuring the SCSI Adapter