background image

8

Serial Mode Select Switches (SW4 to SW10) operate as shown in the circuit diagram below.

2.

Internal switches of the front module

„

 Touch Panel Set SW

Switch 

Location

Switch Name

Factory 

Settings

Description

SW1

Touch Panel 
Set SW

1:ON, 2:ON, 3:OFF, 4:OFF

4-point dipswitch. 
For Touch Panel Set SW details, 
see “

„

 Touch Panel Set SW”.

SW2

1:ON, 2:OFF, 3:ON, 4:OFF

Internal setting.
Do not change. (Factory setting)

Switch 

No.

Description

ON

OFF

Factory 

Settings

Notes

1 to 2

Internal setting

Reserved Reserved

ON

Do not change. (Factory setting)

3

OFF

4

Cancellation function 
of two point touch on 
the touch panel

*1

*1

When two points are pushed, it is considered that middle point between the two points is touched 
according to the nature of the analog resistive touch panel. When the switch, etc. is set on the middle 
point, it will be enabled and may operate. To prevent such a switch from malfunction in case of pushing 
two points, turn ON the SW No.4 in advance, then the middle point will be disabled for two point touch.

Enabled Disabled OFF

The middle point is not considered to be 
touched when the SW is ON. It is considered 
to be touched when the SW is OFF.

SW4
SW9
SW10

SW5

SW7

SW6

SW8

RT(RTS) Automatic 
control

COM

1

SD(TXD)

RT(RTS)

SDA

SDB

RDA

RDB

SW1

SW2

ON

ON

Rear face of the front module

Summary of Contents for APL3700-TA

Page 1: ...ssing please contact your local PL distributor immediately When you order a PL unit built to your specifications that PL package should include each optional item s Installation Guide Please use that guide to check the contents of each optional item s package About the Manual For the detailed information on PL series refer to the following manuals PL3000 Series Hardware Manual PL3000 Series Refere...

Page 2: ...s Soft OFF State is different from Windows System Standby E USB interface 1 port USB2 0 compatible Type A connector is used A B C E D Front LED Indicates Green lit Normal operation power is on Green blinking Soft OFF state Orange lit System monitor error RAS error Touch Panel Self Test Error Orange Red blinking Backlight burnout is detected Not lit Power is OFF LED Indicates Green lit When HDD or ...

Page 3: ...tor is used M Speaker output interface SPK Mini pin jack connector N HDD status lamp HDD0 HDD1 For HDD0 and for HDD1 from left to right O Serial interface COM1 D Sub 9 pin plug type RS 232C RS 422 RS 485 Changeover CI RI 5V Changeover P Serial interface COM2 D Sub 9 pin plug type RS 232C CI RI 5V Changeover Q Serial interface COM3 COM4 D Sub 9 pin plug type RS 232C COM3 and then COM4 from the top ...

Page 4: ...oltage Drop 5ms or less 1 cycle or less Voltage drop interval must be 1s or more 1 1 When the total of the expansion slot power and the external load power exceeds 25W the length of the allowable voltage drop will be 20ms or less For details refer to the chart below Power Consumption 145W or less 145VA or less In Rush Current 40A or less Voltage Endurance AC1000V 10mA for 1 minute between charging...

Page 5: ...et the Windows 2000 s Control panel Power Management option Turn off hard disks selection or the Windows XP s Control panel Performance and Maintenance Power Management option Turn off hard disks selection to turn the hard disk off when the unit is not being operated A setting of 5 minutes is recommended Do not vibrate the hard disk continuously at the same frequency Doing so may cause the hard di...

Page 6: ... Factory setting 2 Implements the logical inversion operation for RAS output Normal Close Normal Open OFF RAS output is a CLOSE state when the SW and the system is ON When the SW is OFF it is the opposite The RAS Output keeps Normal OPEN when the Soft OFF state occurs or the power turns OFF 3 Sets up an enabled disabled state for the front USB port execution control function 1 1 The Setting up an ...

Page 7: ...ver is controlled with the RS RTS signal Set switch number 4 to ON 5 Switches the SD TXD termination resistance ON OFF Inserts termination resistance of 220Ω between SDA and SDB No termination OFF ON ON OFF 3 3 If you use the termination resistance base your settings on the connection specifications 6 Switches the RD RXD termination resistance ON OFF Inserts termination resistance of 220Ω between ...

Page 8: ...ncellation function of two point touch on the touch panel 1 1 When two points are pushed it is considered that middle point between the two points is touched according to the nature of the analog resistive touch panel When the switch etc is set on the middle point it will be enabled and may operate To prevent such a switch from malfunction in case of pushing two points turn ON the SW No 4 in advan...

Page 9: ... Ready 7 RS RTS Request to Send 8 CS CTS Clear to Send 9 CI RI 5V Called status display 5V Output 0 5A 1 2 1 Only COM1 and COM2 are available for switching to 5 V COM3 and COM4 are used exclusively for CI RI 2 Slide switch on the circuit board in the PL unit switches between CI RI and 5 V For details see Internal Switches Shell FG Frame Ground Common with SG Pin RS 422 3 Signal Name Meaning 1 RDA ...

Page 10: ...he panel of a cabinet or enclosure Surrounding air tem perature indicates both the panel face and cabinet or enclosure s internal temperature Be sure that heat from surrounding equip ment does not cause the PL to exceed its standard operating temperature 2 PL Installation 1 Create a Panel Cut following the dimen sions in the following table Also deter mine the panel thickness according to the pane...

Page 11: ...uired to tighten these screws is 0 8 N m Installation uninstallation of the front module and the control box To avoid an electric shock prior to instal lation uninstallation of the front module and the control box confirm that the PL unit s power supply is completely turned OFF via a breaker or similar unit 1 Uninstalling the front module and the control box 1 Unscrew the two attachment screws to ...

Page 12: ...witch to its power cord When the FG terminal is connected be sure the wire is grounded 1 Wiring the AC type power supply cable When the FG terminal is connected be sure the wire is grounded Not grounding the PL unit will result in excessive noise Use your country s applicable standard for grounding Power Cord Specifications Use copper conductors only Wiring When connecting the power code use the f...

Page 13: ...licable standard for grounding Power Cord Specifications Use copper conductors only Power Connector Plug Specifications Accompanying power supply connector is CA5 DCCNL 01 of Pro face or GMVSTBW2 5 3 STF 7 62 of Phoenix Contact When connecting the power code use the following items when performing wiring Items are made by Phoenix Contact Connecting the PL Power Cord 1 Confirm that the power is not...

Page 14: ...t of noise connect a noise reducing transformer The temperature rating of field installed conductors 75 C only Use voltage and noise reducing trans formers with capacities exceeding Power Consumption value Branch Circuit Protective device shall be use for rating 20A for DC24V input device Connect a surge absorber to handle power surges Be sure to ground the surge absorber E1 separately from the PL...

Page 15: ...ows you to securely clamp the USB cable in the cable clamp The USB cable clamp is not compatible with the USB connector on the front face 2 Fix the USB holder with two screws The torque required to tighten these screws is 0 5 to 0 6 N m 3 As the figure shows pass the USB Cable Clamp s band around the depressed sur face of the holder twist the USB Cable Clamp s band around the USB cable pull the ba...

Page 16: ...space around the rear face of the PL unit The temperature must be checked on the final product in which the PL unit is installed For use on a flat surface of a Type 1 Enclo sure CE Marking APL3700 TA unit is CE marked product that conforms to EMC directives and Low Voltage Directives EN55011 Class A EN61000 6 2 and EN60950 1 APL3700 TD unit is CE marked product that conforms to EMC directives EN55...

Reviews: