Installation and configuration
Page 34
Note:
Any unused ports should be terminated by a 120 Ohm resistor across
RX A and RX B signals. COMMON signals should be grounded.
All sensor ports can be configured via the Interface settings menu which can
be found under the
‘Home’ > ‘System settings’ > ‘Interfaces’
menu option.
The Interface settings menu also includes the ability to disable the requirement
for external GNSS sensors to provide a DTM (Datum) sentence.
3.4.6
Alarm connections
The AIS transceiver also provides connections to the alarm relay contacts.
The alarm relay connections are described in Table 3.
Table 3 Alarm relay connections
Alarm connection
Function
Contact rating
COM
Alarm relay common
connection
2A at 220VDC or 60W
maximum
NC
Alarm relay normally
closed connection
I
f an external GNSS device which does not provide a DTM
sentence is connected to the AIS transceiver and the AIS
transceiver is configured to require DTM sentences, the
external GNSS data will not be accepted by the AIS
transceiver. If no DTM sentence is required the WGS84
datum will be used as a coordinate origin and the
external GNSS device must be configured to output
position using this datum.
!
Summary of Contents for CLA2000
Page 1: ...CLA2000 CLASS A AIS TRANSPONDER Installation and Operation Manual...
Page 10: ...Table of contents Page 8...
Page 18: ...Notices Page 16...
Page 20: ...Introduction Page 18...
Page 26: ...Installation and configuration Page 24 Figure 5 Desk mounting the AIS transceiver...
Page 42: ...Installation and configuration Page 40...
Page 86: ...Technical information Page 84...
Page 98: ...Technical specification Page 96...
Page 102: ...Installation record Page 100...
Page 103: ......