Installation
Page 46
The alarm relay is rated to 220VDC or 2ADC or 60W maximum. The alarm connections provided at the power
connections are a duplicate of the those available via the junction box and described in section 4.4.
A chassis ground stud is provided on the rear panel of the transceiver. Note that the transceiver chassis is
isolated from the incoming power supply so this stud must not be connected to power supply ground.
4.4.6
PC data connection
A 9 way D-type connector is provided on the rear panel of the
Smarter Track Class A
transceiver. This
interface allows direct connection to a PC RS232 interface and can be used for installation, diagnostics or
external display connection. The default configuration for this interface allows connection of an ECDIS or
charting system and duplicates the ‘External display’ port in the junction box.
Figure 48 PC data (RS232) connection
The pin allocation for the 9 way D-type socket on the rear panel of the transceiver is shown in Table 7.
Table 7
Pin allocation for the 9 way D-type socket
Transceiver 9 Way
D-type pin
Signal
Function
1
No connection
2
RS232 Transmit
Connect to PC RS232 receive
3
RS232 Receive
Connect to PC RS232 transmit
4
No connection
5
RS232 Ground
Connect to PC RS232 ground
6
No connection
7
No connection
8
No connection
9
No connection
PC
data
(RS232)
c
onne
c
tion
The RS232 port is galvanically isolated from the incoming power supply.