7

d. AMPLIFIER/REPEATER STATUS

The DA4000SBR unit is designed with a status/fault indicator to indicate proper unit 
functionality.  The chart below details the different LED color indicators.  

LED 

Status

GREEN solid light

Normal Status

YELLOW/ORANGE 
flickering light

Degree of cellular transmission activity or may stay 
green with cell phones operating on 1900 MHz.

Solid RED light

TURN OFF, Fault needs immediate corrective 
action 

No light

No power to the DA4000SBR amplifier/repeater or 
unit is damaged

If a red flashing light appears on the DP515 power supply, relocate the inside and outside 
antennas until the power supply has a constant green light. The power supply can be reset 
by unplugging the cigarette adapter from the power source.  

GREEN solid light

Normal status

Flashing RED light

Power supply stops power to repeater until 
antennas are properly installed.

Green light on repeater – shows normal Status and DA4000SBR is operating normally
unless coverage area is only 1-2’ from inside antenna. If coverage area is only 1-2’, 
DA4000SBR repeater is automatically powering down to prevent an oscillation. Re-
locate antennas until coverage area is greater.

Green/yellow/orange flickering light on repeater - shows that cellular activity is being
transmitted through the DA4000SBR unit unless cell phone is operating on 1900 MHz. 
The light will remain green with low levels of cellular transmission and change to 
flickering yellow/orange as transmission increases. The light may remain green with low 
levels of transmission. When a yellow/orange light is present, it must always go back to 
green when call is finished. If it does not go back to green, re-locate antennas until light 
goes back to green.

Solid Red light on Repeater – indicates a fault. Turn OFF power switch and proceed 
with the following corrective actions:

x

The red light indicates that the inside and outside antennas are located too close to 
each other and need to be re-located. A typical installation requires that the inside 
and outside antennas have a minimum separation distance of 25 feet and be 
separated by an exterior wall.  If the inside and outside antennas are not 25 feet 
apart or more, re-locate the antennas. 

x

If the outside and inside antennas are separated by 25’ or more and an exterior 
wall, the red light may be indicating the use of analog phones. Contact Digital 
antenna if you are using an analog phone.

No light on Repeater – indicates improper installation and the power supply is stopping 
power to the repeater or no power is available. Proceed with the following corrective 
actions:

x

Only after all cables and antennas are securely attached, verify that the power 
switch on the DA4000SBR unit is in the ON position.

Summary of Contents for PowerMax 4KSBR-50M

Page 1: ...Avenue Sunrise FL 33351 t 954 747 7022 f 954 747 7088 Read Instructions before installing If you do not understand instructions seek professional installation D I G I T A L A N T E N N A Repeater DA40...

Page 2: ...installation Guidelines 5 a Installation Tools 5 b Installation Procedure 5 c Electrical Power 6 d Amplifier Repeater Status 7 e Interior Coverage Problems 8 f Coaxial Cable Recommendations 8 5 Marin...

Page 3: ...R system complies with all FCC IC UL rules regulations and codes Follow all guidelines in the installation and instruction manual and read completely before beginning the installation procedure Do not...

Page 4: ...nnection with the use inability to use or performance of the information services products and materials available from this manual These limitations shall apply notwithstanding any failure of essenti...

Page 5: ...nal Antenna Low loss Cable Cellular Booster Internal Directional Antenna Marine Wireless Repeater Installation RV Wireless repeater Installation Low loss Cable 2006 Digital Antenna Inc Internal Direct...

Page 6: ...a central location for the DA4000SBR repeater unit within 6 of a 12VDC power receptacle If the location of the DA4000SBR unit is not mounted within reach of the supplied 50 cable a 25 extension cable...

Page 7: ...nsmitted through the DA4000SBR unit unless cell phone is operating on 1900 MHz The light will remain green with low levels of cellular transmission and change to flickering yellow orange as transmissi...

Page 8: ...flect the signal Inspect the coverage area rearrange any objects in the path of the cell signal or relocate the indoor antenna x Output Power Control The DA4000SBR has an internal output power control...

Page 9: ...bles are securely attached 4 The DA4000SBR unit has four mounting holes that can be fastened to a secure surface fastening hardware not included When mounting the DA4000SBR unit the inside antenna mus...

Page 10: ...UHF Female Inside Antenna Port Mini UHF Female DC Power Coaxial ID 2 5mm OD 5 5mm center positive x Indicator Multi color status indicator x Power Switch Slide switch toward LED ON Outside Antenna PN...

Page 11: ...8 5dB per 100 Cable PN 240 15NM x Length 15 x Impedance 50 Ohm x RF connectors Type N male and mini UHF male factory attached x Attenuation at 800 MHz 7 1dB per 100 x Attenuation at 1900 MHz 11 2dB p...

Page 12: ...0 cable 340 50NM only 340 25NE 50 PowerMaxTM DA340 Cable Assembly for outside antenna 340 50NM 75 PowerMaxTM DA340 Cable Assembly for outside antenna 340 75NM 100 PowerMaxTM DA340 Cable Assembly for o...

Page 13: ...lable to authorize technical support and or establish a return authorization For installation support contact your dealer For system warranty issues contact Digital Antenna Technical Support between t...

Reviews: