R232 / R232-48VDC Installation Guide
Page 8 of 8
5 SPECIFICATIONS
Model
R232
R232-48VDC
Input Ports
32 (labeled 1 – 32)
Output Ports
2 (labeled A – B)
Connectors
“F” Type 75
W
Operating Bandwidth
5 - 2.0GHz
Flatness
± 1.5 dB Over operating bandwidth
Input Signal Level
M15dBmV
Minimum -11dBmV
Gain:
+20 dB Input to Output
Isolation (port – port)
-55 dB
Return Loss
>15dB
Routing
Non-blocking 32 x 2 matrix.
Any input can be routed to either or both outputs.
Front Panel Display
Output A - Green
Output B - Amber
Power– Blue
LAN Interface
TCP/IP Ethernet 10/100 BASE-T Ethernet
IEEE 802.3
Network Connection
RJ-45 connectors suited for wiring CAT-5 or above
Indicators
Green link & data indicators
Chassis
19.0” W x 12.75” D x 1.75” H
(48.3 cm W x 32.385 cm D x 4.45 cm H)
1RU EIA rackmount)
Weight
8 lbs. (3.63 kg)
Power Input
90-240 VAC,
±
2%
50-60Hz
42 – 52 VDC
Nominal Power
Consumption
0.19 A @ 120VAC
(22.5 Watts)
0.25A @ 48V
(12 Watts)
Power Connection
Right-angle removable
IEC power cord
Two-wire removable
terminal strip with
retaining screws
Wire gauge max: 16
Power supply protection
Externally accessible fuse
2.5 A Slo-Blo 5 x 20 mm
Internal fuse
1A Slo-Blo 5 x 20mm
Operating temperature
-20 ~ +70°C
-10 ~ +60°C
Operating humidity
20 ~ 90% RH non-condensing
Table 1 R232/R232-48VDC Specifications.