5  SPECIFICATIONS 

 

Model 

R232 

R232-48VDC 

Input Ports 

32 (labeled 1 – 32) 

Output Ports 

2 (labeled A – B) 

Connectors 

“F” Type 75

W

 

Operating Bandwidth 

5 - 2.0GHz 

Flatness  

± 1.5 dB Over operating bandwidth

 

Input Signal Level 

M15dBmV 

Minimum -11dBmV 

Gain: 

+20 dB Input to Output 

Isolation (port – port) 

-55 dB 

Return Loss 

>15dB 

Routing 

Non-blocking 32 x 2 matrix. 

Any input can be routed to either or both outputs. 

Front Panel Display 

Output A - Green 

Output B - Amber 

Power– Blue 

LAN Interface

 

TCP/IP Ethernet 10/100 BASE-T Ethernet 

IEEE 802.3

 

Network Connection 

RJ-45 connectors suited for wiring CAT-5 or above

 

Indicators 

Green link & data indicators

 

Chassis 

19.0” W x 12.75” D x 1.75” H 

(48.3 cm W x 32.385 cm D x 4.45 cm H) 

1RU EIA rackmount)

 

Weight 

8 lbs. (3.63 kg) 

Power Input 

90-240 VAC, 

±

 2% 

50-60Hz 

42 – 52 VDC 

Nominal Power 

Consumption 

0.19 A @ 120VAC 

(22.5 Watts)

 

0.25A @ 48V 

(12 Watts) 

Power Connection 

Right-angle removable 

IEC power cord 

Two-wire removable 

terminal strip with 

retaining screws 

Wire gauge max: 16 

Power supply protection 

Externally accessible fuse 

2.5 A Slo-Blo 5 x 20 mm 

Internal fuse 

1A Slo-Blo 5 x 20mm 

Operating temperature 

-20 ~ +70°C 

-10 ~ +60°C 

Operating humidity 

20 ~ 90% RH non-condensing 

 

Table 1 R232/R232-48VDC Specifications. 

 

Summary of Contents for R232

Page 1: ...igital Alert Systems Inc Information herein is considered accurate at the time of publication We constantly strive to improve our products and services therefore some specifications are subject to cha...

Page 2: ...8 Table of Contents 1 PRODUCT OVERVIEW 3 1 1 INTRODUCTION 3 2 POWER CONNECTIONS 4 2 1 1 R232 POWER CONNECTIONS AC 4 2 1 2 R232 48VDC POWER CONNECTIONS DC 5 3 MOUNTING 6 4 TEST CABLE WIRING 7 4 1 F CO...

Page 3: ...es of this document the term R232 will be used synonymously unless there is a need to differentiate the models The R232 front panel features a row of LED indicators to indicate the presence of power a...

Page 4: ...yle Although the inputs differ the connection points and cable arrangements are the same Both models feature the patented Pocket Power Supply which is a unique opening on the right side of the chassis...

Page 5: ...ted to the chassis as shown in Figure 6 while the mating connector can be easily removed to facilitate installation of the power cabling IMPORTANT NOTE CLOSELY OBSERVE THE CONNECTION POLARITY TO AVOID...

Page 6: ...th DC power cabling installed and properly configured Once power connections are made the unit is ready for mounting 3 Mounting The R232 is designed to be mounted in a standard Electronic Industries A...

Page 7: ...on component and must be treated as such Therefore it is critical that NO EXCESSIVE FORCE BE APPLIED TO THE INPUT OUTPUT CONNECTORS CRITICAL NOTE Do not exceed 10 in lbs 1 12 N m of torque on any F co...

Page 8: ...net 10 100 BASE T Ethernet IEEE 802 3 Network Connection RJ 45 connectors suited for wiring CAT 5 or above Indicators Green link data indicators Chassis 19 0 W x 12 75 D x 1 75 H 48 3 cm W x 32 385 cm...

Reviews: