Page 2 of 4
Aiphone™ LE / LS series 3-wire Call Station Installation
•
Set the internal
ST-MIC
switch to the
ST
setting
•
Remove Aiphone shorting link between
E and - terminals
•
Connect
SPKR 8Ω+
and
SPKR 8Ω-
(J2-
6 and J2-
7) to the “1” and “E” terminals
on the Aiphone call station
•
Connect
TALK
(J2-
5) to Aiphone “–“
(minus) terminal
•
Connect
GND
(J2-4) to the shield of the shielded wire. Do not connect the
shield at the call station
Aiphon
e™ IE / IF series 2-wire Call Station Installation
•
Set the internal
ST-MIC
switch to the
MIC
setting
•
Connect
GND
and
TALK
(J2-4, J2-5)
to Aiphone terminals 1 and 2 (polarity
independent)
•
Connect
GND
(J2-4) to the shield of
the shielded wire. Do not connect the
shield at the door station
Call stations with a separate microphone, speaker and Call button
•
Set the internal
ST-MIC
switch to the
MIC
setting
•
Connect
MIC+
and
MIC-
(J2-1, j2-2) to
the call stations microphone
•
Connect
GND
(J2-4) to the shield of
the shielded wire. Do not connect the
shield at the call station
•
Connect
SPKR 8Ω+
and
SPKR 8Ω-
(J2-6 and J2-7) to the call stations
speaker terminals
•
Connect
TALK
(J2-5) to one contact
on the call station’s TALK button
•
Connect the other contact on the
call station’s TALK button to
GND
(J2-4)
or jumper it to one of the speaker terminals (this wire should be limited to
10ft or 3 meters)
Driving an Analog Paging Amplifier
The IP7-ST/STX has the capability to drive a
balanced
600 Ohm input of an
analog amplifier using
SPKR 8Ω+
and
SPKR 8Ω-
(J2-6 and J2-7). Set the
IP7’s volume level to 6 and adjust the amplifier’s volume control accordingly.
If the analog amplifier uses an
unbalanced
input, then the IP7’s Line
Out and GND (J2-3 and J2-4) must be used instead of SPKR 8
Ω+
and SPKR 8Ω-.
Failure to do so will damage the IP7 and void its
warranty.
Relay Options
•
The integrated
Relay
uses
COMMON
(J3-2), along with
NO
- Normally
Open (J3-1) or
NC
- Normally Closed (J3-3). Use Admin Console to
configure the options
Sensor Options
•
The integrated
Sensor
can be used to monitor the status of a door by
connecting
Sensor
(J3-5) and
GND
(J3-6) to a contact closure sense
switch. Use Admin Console to configure the options
Power Options
•
Power over Ethernet (PoE - 802.3af compliant) - requires 7 watts from
Power Source Equipment (PSE)
•
9VDC - 32VDC external via
J1-1
and
J1-2
connectors or
Aux Power
2.1mm barrel connector
•
An external power supply, if detected, overrides PoE power
Network Installation
•
Connect an RJ-45 cable between the
Ethernet 10/100
connector and a
10/100 network switch
•
On the
IP7-STx
, after the
Ethernet 10/100
is connected, another IP device
can be connected to
Port 2 10/100
jack
Mounting Instructions
The IP7 series is design to be mounted on standard 35mm DIN rail or
surface mounted using the surface mounting plate.
•
DIN Rail Clip
– Tilt top of unit (J1, J2, J3 connectors facing up with Volume
buttons facing forward) back towards the DIN Rail until the IP7 DIN clip
catches the top of the rail. Press in at the bottom of the IP7 to snap into
place
•
Surface Mount Plate
– Snap the surface mount plate in half and secure it
to the back of the unit using the provided screws so that the mounting
holes extend past the edges of the case
Aiphone LE, LS series
J1
J2
J3
Aiphone IE, IF series
J1
J2
J3
No Connection
J1
J2
J3
Call