Installation
•
Plug the IP7-MSR
directly into the IP7-
SE8’s
J1
,
J2
and
J3
connectors. (The IP7-
SE8’s Microphone,
Speaker and Relay
connectors are used by
the IP7-MSR. All other
connectors are passed
through to the IP7-SE8)
•
Attach the included cable
to the
RJ-10
port on the
IP7-MSR and the
EXT
I/O
port on the IP7
•
Using twisted
shielded
18 AWG wire, connect the
SPKR 8
Ω+
(J2-6)
and
SPKR 8
Ω-
(J2-7)
of the IP7-MSR to a suitable speaker. The 8
Ohm speaker should be no more than 200 feet away from the IP7-
SE8
•
Connect the shield
to the IP7’s
GND (J2-4)
connector.
Do not connect
the shield to the speaker
•
Power up the IP7-SE8 and connect it to the network
Configuration
•
When configuring the IP7-SE8 using the TalkMaster FOUCS
Administrator Console, open the
IP Endpoints
Options 1
tab.
Under the
Relay Mode
, select the
Activate On
…
option and then
check
MIC
IP7 and Digital Acoustics® are trademarks of Digital Acoustics LLC.
Other trademarks are the property of their respective owners.
INT-IP-2GangGSG - 2018-03-23 - All Rights Reserved ©2018