Maintenance Guide

Veterinary Dental Cassette Kit

Doc No. : TM-723-EN 

Rev 1.2.1 Nov 2014

 

Part No. : CR-FPM-03-002-EN 

Digiray

FireCR

Quantor

 are trademarks of 

Digiray

 Corp

, South  Korea,  and  its  affiliates.   All 

other  trademarks  are  held  by  their  respective  owners  and are  used  in  an  editorial  fashion  with 

no  intention  of  infringement.   The  data  in  this  publication are  for  illustration  purposes  only  and 

do  not  necessarily  represent  standards  or  specifications, which  must  be  met  by 

Digiray

 Corp

.  

All  information  contained  herein  is  intended  for  guidance  purposes  only,  and  characteristics  of 

the  products  and  services  described  in  this  publication  can  be  changed  at  any  time  without 

notice.   Products  and services  may  not be  available  in  your  local  area.   Please  contact  your 

local  sales  representative  for  availability  information.   

Digiray

  Corp.

  strives  to  provide  as 

accurate  information  as possible, but shall not be responsible for any typographical error. 

©  Copyright 201

9

 

Digiray

 Corp.

  All rights reserved. 

Summary of Contents for Fire CR

Page 1: ...not necessarily represent standards or specifications which must be met by Digiray Corp All information contained herein is intended for guidance purposes only and characteristics of the products and...

Page 2: ...Cassette Kit TM 723 EN 2 Contact Digiray Corp 825 Unitech Venture Town 142 Ilsan ro Ilsandong gu Goyang si Gyeonggi do 10442 Republic of Korea Tel 82 31 932 8401 Fax 82 31 927 9988 Website www digira...

Page 3: ...ges have been made to delivered system and accessories the warranty by Digiray Corp becomes void Digiray Corp will not accept any responsibility or liability for the proper functioning of the product...

Page 4: ...nd operation of this device should only be undertaken by qualified trained personnel The operator should study instructions and precautions carefully before starting to use the device listed here and...

Page 5: ...ccur unplug the device from the electrical outlet and contact authorized service personnel The power cord or power adapter is damaged An object has fallen into the device The device has been exposed t...

Page 6: ...e 4c 48x54 mm 2ea 6 Size 4 76x57 mm 1ea Veterinary Dental Cassette Moving Plate 2 Imaging Plate Cleaning Protect your investment Dust and dirt are piled up on CR imaging plate leading to image artifac...

Page 7: ...e surface of the protective layer and they appear on the image The phosphor layer has peeled away from the support layer 2 2 Imaging Plate Cleaning Tools Moving plate extracting tool Imaging plate cle...

Page 8: ...tte the Cassette Lock Releaser should be linked up with the Cassette The the Cassette Lock Releaser are pressing those buttons during it is linked up with the Cassette correctly Stand the Cassette on...

Page 9: ...hanol directly on to the imaging plate Make sure the imaging plate surface is completely dry before using the imaging plate WARNING Be sure not to damage the imaging plate Do not scratch the imaging p...

Page 10: ...ck Releaser Make sure both of buttons are pressed Insert moving plate into the cassette WARNING Do not put the imaging plate upside down when it is inserted Do not insert the moving plate in wrong dir...

Page 11: ...Kit TM 723 EN 11 DANGER Never press push buttons of the cassette with upside down position A crash will cause the damage of the imaging plate and moving plate which can affect X ray image quality Alw...