DR4024 DIGISERVO (v1.31)
Pagina / page / Seite / page 17
CV CV Definition
Range Value
118 Switching output 2 (OUT 6)
For settings see CV117
0-255
1
119 Switching output 3 (OUT 7)
For settings see CV 117
0-255
1
120 Switching output 4 (OUT 8)
For settings see CV 117
0-255
1
121 Position A for servo 1
CVs 121-136 contain the various end positions of the servos. Each servo has 4 final po-
sitions: A, B, C, D. These end positions can be selected using function mapping
(see page 18)
0-255
224
122 Position C for servo 1
0-255
176
123 Position B for servo 1
0-255
32
124 Position D for servo 1
0-255
80
125 Position A for servo 2
0-255
224
126 Position C for servo 2
0-255
176
127 Position B for servo 2
0-255
32
128 Position D for servo 2
0-255
80
129 Position A for servo 3
0-255
224
130 Position C for servo 3
0-255
176
131 Position B for servo 3
0-255
32
132 Position D for servo 3
0-255
80
133 Position A for servo 4
0-255
224
134 Position C for servo 4
0-255
176
135 Position B for servo 4
0-255
32
136 Position D for servo 4
0-255
80
137 CVs 137-140 contain the mass simulation values.
If the value is not equal to 0, the servo will alternately add and subtract this value at
the end position, whereby the value is also decreased by 1 each time, until the value
reaches 0.
This causes the servo to oscillate back and forth less and less around its end position. A
precondition for this working is that the end po the bounce value is less than
255 and that the end position - the bounce value is greater than 0.
0-63
0
138 Mass simulation value for servo 2 (see CV137)
0-63
0
139 Mass simulation value for servo 3 (see CV137)
0-63
0
140 Mass simulation value for servo 4 (see CV137)
0-63
0