![Digikeijs DR5013 DIGIREVERSE Instruction Manual Download Page 28](http://html1.mh-extra.com/html/digikeijs/dr5013-digireverse/dr5013-digireverse_instruction-manual_2497385028.webp)
DR5013 DIGIREVERSE
P 28
www.digikeijs.com
® R
-
Bus, B
-
Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS
-
Bus is a trademark registered in the name of Lenz
Stand 2021
-
07
-
06
5.4 DR5013 connection with sensor tracks (S1,S2) and LocoNet
This connection example shows the use of the DR5013 in conjunction with sensor tracks (S1,S2). With this connection, the DR5013 automatically reverses the polarity (short
-
circuit
-
free) and may be able to switch the entry/exit switch automatically on exit. Via LocoNet® various information (Railcom® information, feedback, short
-
circuit message, switch
setting commands, etc.) is transmitted to the central unit and can be evaluated accordingly.
Functionality:
The turnout was e.g. switched to bent. The DR5013 "reads" the executed turnout circuit via the track Input/LocoNet® and thus recognizes which polarity is required in the revers-
ing loop and adjusts it if necessary. As soon as the locomotive reaches the area of the reversing loop (track), it is reported as occupied to the control centre via LocoNet® with the
integrated occupancy detector and can, for example, be evaluated with a control program. At the same time, the Railcom® data of the locomotive (address, QoS messages, etc.)
are read out in the entire reversing loop track (S1,S2,Track) and also reported to the control centre. The locomotive reaches sensor track 2 (S2). The DR5013 now recognizes that
the locomotive is on its way to the exit. The polarity of the reversing loop is switched according to the polarity of the exit. In addition, the DR5013 can "correct" the turnout at this
moment so that a smooth exit is possible. If the turnout is in a straight line, the sequence is the same except that the order of the sensor tracks is different (S2
-
> S1).
Terminal assignment:
S0
<not used>
S1
Sensor track 1
S2
Sensor track 2
S3
<not used>
Track
reversing track
Necessary track separation
Here we describe which settings are to be made in the DR5013 config tool.
Sensor track settings:
In the input fields of the sensor tracks S1, S2, Track (T) the feedback contacts
must be entered which are to be used for the respective sensor tracks. The
feedback numbers for S1,S2 and Track (T) are assigned directly in the
DR5013. Since S0 and S3 are not used, a 0 must be entered in the input win-
dows for S0 and S3.
Turnout mode:
In this example the settings Both should be used for the turnout mode. The
magnetic article address of the turnout must be entered.
Turnout status:
Both settings are possible for the basic position of the turnout.