![Digikeijs DR 4088LN Series Instruction Manual Download Page 4](http://html.mh-extra.com/html/digikeijs/dr-4088ln-series/dr-4088ln-series_instruction-manual_2497379004.webp)
DR4088LN
-
CS / GND / OPTO
2021
-
04
-
21
P 4
www.digikeijs.com
® R
-
Bus, B
-
Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS
-
Bus is a trademark registered in the name of Lenz
2.0 Product overview
2.1 General product information
The DR4088LN
-
xx is a feedback module that can be connected to the control panel via LocoNet®.
The DR4088LN
-
xx has 16 feedback inputs.
The DR4088LN
-
xx is available as CS version (current sensor 2
-
wire track), OPTO version (connection of reed contacts, 3
-
wire track signal to track ground) and
GND version (3
-
wire track).
2.2 Technical specifications
The connection terminals of the 16 feedback units are designed for a cross
-
section of 0.5mm², the two terminals for "C" are designed for a cross
-
section of
0.75mm².
Important
! DR4088GND 3
-
wire operation:
Due to the H
-
bridge (track output) in the DR50xx, feedback devices in the DR4088GND version must not be used against track ground, as
is usually the case with 3
-
wire tracks. This inevitably leads to the destruction of the DR50xx.
If a 3
-
wire driver still wants to drive with the DR50xx and report back against track ground, the DR4088OPTO
can be used.
Number of
inputs
Suitable
for
Minimum load for safe
reporting
Max. load per
contact Load
per contact
Max. load per contact
Load capacity
per contact for
max. 100 ms
Peak load for 8 feedbacks
at "C" total.
DR4088CS
2 x 8
2 conductors
2 mA
2 A
5 A
6 A an
„
C
“
DR4088OPTO
2 x 8
3 conductors
when using the
DR50xx
-
-
-
DR4088GND
2 x 8
3 conductors