background image

When the “totale gain of altitude” is visualized the unit of measure

icon

” over the number flashes. This instrument is always

represented in tens of meters or tens of feet.

- The second numerical display visualizes the minimum and

maximum value of the analog vario.

- The third numerical display the minimum and maximum value of

the air speed “

”.

In order to alternatively visualize the minimums and maximums

values press the

key.

- The fourth numerical display visualizes the progressive number of

the selected flight, in order to select a different flight press

keys, a higher number indicates a more recent flight.

- The fifth multifunction display shows alternatively: duration of the

flight and flight takeoff time; in order to choose between the three

functions press the

key.

The date is displayed in the “day month” format , the duration of the

flight (

) in “hours:minutes” and

takeoff time (

) in

“hours:minutes”.

The memory of the recorder contains last 100 recorded flights.

In order to delete all recorded flights :

press

then

twice, the word

is displayed , then press and

hold pressed the

key until hearing a triple sound.

With the VL100 and PC switched off, connect your flight instrument to
your PC via the “PC CABLE” or the “FlashPro100” unit. Turn on the PC
and the Vl100 , select the menu “LINK” in the Vl100 .
The VL100 is now connected to your PC and ready to accept
commands from your Pc Software. ( visit www.digifly.com for more

mt/ft

ias

chrono

Time

“peak”

or

and

5

PC-LINK

Page 8

Summary of Contents for Flyer

Page 1: ...User manual Vl100 flyer rev 1 3 firm 7 1 ...

Page 2: ...rchase dealer s name and model and serial number of the product The Digifly guarantee may not apply if the documents have been altered in any way or made illegible repairs or product modifications and alterations have been executed by unauthorised service organisations or persons damage is caused by accidents including but not limited to lightning water or fire misuse or neglect In case your Digif...

Page 3: ...e 4 2 2 2 Analog Vario Page 4 2 2 3 Integrator Vario Page 4 2 2 4 Acoustic Vario Page 5 2 2 5 Total Energy Compensation Page 5 2 3 Air speed Page 5 2 4 Barometer Page 6 2 5 Thermometer Page 6 2 6 Time Chrono Page 6 2 8 Batteries Level Page 6 2 7 Voltmeter Batteries Page 6 4 5 Link PC 6 Upgrade Software 7 Technical features Quick reference setup parameters Page 8 Page 9 Page 9 Page14 Notes Page11 F...

Page 4: ...meters of the instrument To go to the main menu press the key and in the upper part of the screen will appear the word and in the lower part the name of the selected submenu In order to search the required submenu press the keys and confirm with the key In order to return to the main menu from a submenu or to exit from the main menu press the key Submenu are the following recorder activation altim...

Page 5: ...d It is displayed on the analog bar to the left of the screen Indicates the integrated value average of the vertical speed It is displayed on the second numerical display from the top of the screen when the symbol appears To set up the time of integration edit sophisticated produces with a long pressure the key The adjustment of the 3 altimeters is possible in the submenu Parameters ALT1 ALT2 ALT3...

Page 6: ...gs and viceversa A starting value for hang glider 65 a zero value excludes the compensation The air speed is displayed on the third display from the top of the screen when the icon appears To set up the threshold of the stall alarm modify the parameter n 6 in the submenu In case of small errors is possible to calibrate the air speed propeller editing the parameter n 8 in submenu It s value is the ...

Page 7: ... To adjust the Date and Time modify following parameters n 10 hour n 11 minutes n 12 day n 13 month n 14 year in the submenu In order to set the multifunction display to show the battery voltmeter press the keys example means 2 8 Volts The batteries level is continually monitored and is displayed on the fourth digital display The level is displayed as a percentage from 0 to 90 in 10 steps for exam...

Page 8: ...hen the altimeter is displayed and the unit is set to display in feet the altitude is indicated in tens of feet low bat In order to START the recorder star To STOP the recorder stop In order to visualize a flight peak Warning Insert new batteries within a minute from the removal of the old ones in order to avoid the loss of the Date and Time data In this case adjust them again see 2 6 3 Units of m...

Page 9: ...on display shows alternatively duration of the flight and flight takeoff time in order to choose between the three functions press the key The date is displayed in the day month format the duration of the flight in hours minutes and takeoff time in hours minutes The memory of the recorder contains last 100 recorded flights In order to delete all recorded flights press then twice the word is displa...

Page 10: ...and maximum of last 100 flights with altitude vario anemometer total gain of altitude of the flight duration takeoff date and time PC Connection Upgradable flash software with optional FlashPro100 6 Software Upgrade 7 Technical features 3 altimeters 9000 mt 29527 ft with adjustable QNH Vario with dynamic filter Vario with adjustable sensitivity Vario total energy compensation presettable Vario ana...

Page 11: ...cable interface Variable units of measure Battery life 200 h Dimensions 135x72x37 mm Weight 200 g battery included 2 Years warranty Page 10 ...

Page 12: ...Notes Page 11 ...

Page 13: ...Notes Page 12 ...

Page 14: ...ometric variation major of 2 mt in less than 4 seconds To STOP the recorder press the key the message will appear and then press the key within two seconds to confirm With 1 in order to end recording just press the key or turn it off pressing the key for at least 3 seconds 0 OFF 1 ALWAYS 2 AUTO dft 2 1 30 Variation in MT default 2 1 30 maximum time of variation in SEC default 4 This takeoff analys...

Page 15: ...0 1m s vert spd sound tone 0 2 0 vert spd sensitivity 1 10 1 vert spd integrator 0 60 0 sec stall alarm threshold 0 150 20 km h tot energy compens 0 100 0 air speed calibration 50 200 100 barometer calibration 2000 xxx 0 1 mB hours 0 23 xx hour minutes 1 59 xx minute day 1 31 xx day month 1 12 xx month year 0 99 xx year 15 AUTR 16 R MT 17 R TI Recorder mode 0 2 2 1 12 2 sec M 0 99 4 mt 0 OFF 1 ALW...

Page 16: ...ight recorder press and normal pressure of the key long pressure of the key min 2 second On off 5sec Volume off med max Battery State ex b80 80 To STOP the flight recorder press and Integr vario Air speed Display multif Batteries volt Barometer Thermometer time chrono Menu Altimeters 1 2 3 Zero alti Display ...