DQ & MQ-Rack User Guide
1.5 Using the Q-Rack Menu System
15
MADI Sync Menu (MQ-Rack only) ................................................................
This page allows selection of the MQ-Rack sync source.
When selecting a sync source:
Auto
will automatically sync to any connection with a clock signal. If the rack is not receiving a connection with
a valid clock signal it will use its internal sync.
MADI MAIN
and
MADI AUX
sockets can be given priority so that
if a clock signal comes into the rack it will sync to the port with priority.
Selecting the
Main
or
Aux
setting in the
Select
parameter forces the active sync source to be the selected
connection and is not affected by the priority option.
The
Active
parameter shows which socket the rack is currently syncing to.
The
Lock
parameter displays from which sources a stable clocking source is received.
Out Routing Menu (MQ-Rack only) ..............................................................
The
Out Routing
menu is for selecting which MADI inputs from a console can output via the MQ-
Rack’s 24
physical outputs.
Internal SR Menu (MQ-Rack only) ...........................................................
The
Internal SR
menu allows selection of the rack’s samp
le rate.
This is only possible to sync from the internal clock if the
MADI Sync Active
is internal.
Available options are
48K
and
96K