AT commands
I/O settings commands
Digi XBee® 3 802.15.4 RF Module User Guide
157
Set the parameter value to the number of button presses that you want to simulate. For example,
send
CB1
to perform the action of pressing the Commissioning Pushbutton once.
Parameter range
1, 4
Parameter
Description
1
Keeps device awake for 30 seconds.
4
Restore defaults (equivalent to sending an
).
Default
N/A
D1 (DIO1/ADC1/TH_SPI_ATTN Configuration)
Sets or displays the DIO1/ADC1/TH_SPI_ATTN configuration (Micro pin 30/SMT pin 32/TH pin 19).
Parameter range
SMT/MMT: 0, 2 - 5
TH: 0 - 5
Parameter
Description
0
Disabled
1
SPI_ATTN for the through-hole device
N/A for surface-mount device
2
ADC
3
Digital input
4
Digital output, low
5
Digital output, high
Default
0
D2 (DIO2/ADC2/TH_SPI_CLK Configuration)
Sets or displays the DIO2/ADC2/TH_SPI_CLK configuration (Micro pin 29/SMT pin 31/TH pin 18).
Parameter range
SMT/MMT: 0, 2 - 5
TH: 0 - 5