![Digi TransPort WR41 Installation Manual Download Page 10](http://html.mh-extra.com/html/digi/transport-wr41/transport-wr41_installation-manual_2496499010.webp)
TransPort® WR41 Utility Installation Guide
Page 10
4 Mounting
A mounting kit is provided which includes:
• 2 x Mounting flanges
• 4 x Screws, 1/4” Phillips flat head
Step 1)
Fasten the mounting brackets to the top and bottom of the rear side of the enclosure with the
1/4”-20 x .25” SS Phillips screws provided. Torque limit -20 in. lb.
Step 2)
Select the location to mount the device.
Note:
The TransPort WR41 Utility should be mounted to a rigid vertical surface with the knockout holes
facing down and the dual cellular antennas facing up. There are two mounting flanges on the base of the
unit. Dimensions are approximately 10” x 12” x 6”.
Step 3)
Remove the seal plugs on either the bottom or rear surface of the device. Hole sizes are as follows:
•
3 holes at 1/2” NPT
•
3 holes at 1” NPT
Note:
Conduits or fittings are not provided. It is the responsibility of the installer to determine which
hardware to use.
Note:
Bonding between conduit is not automatic and must be provided as part of the installation.
Step 4)
Secure the device to the vertical surface with mounting hardware (not provided). The cover is
secured by four corner screws. Torque limit -5 in. lb.
•
Operating temperature: -15° C to +55° C (+5° F to +131° F)
•
Storage temperature: -20° C to +60° C (-4° F to +140° F)
• Altitude maximum: 2000 meters (6561 ft.)
4.1 Cable Installation
The RJ45 connector in the TransPort WR41 Utility is pre-wired to be straight through to the RS232 connection.
Note:
If you require an RS232 connection you must provide your own cable.
RJ45 Serial Pinout
RJ45
RS232
1
RTS
2
DTR
3
RxD
4
NC
5
GND
6
TxD
7
DCD
8
CTS