4  General Specifications 

Model numbers 

81-MR4110-SSEU-00 
81-MR4110-SSEU-01 (MR4110 with GPS)  
81-ER4110-SSEU-00 
81-ER4110-SSEU-01 (ER4110 with GPS) 
81-HR4110-SSEU-00 
81-HR4110-SSEU-01 (HR4110 with GPS) 

Power supply 

12V DC / 1.5A 

Dimensions 

W160 x D120 x H32 mm 

Weight 

0.53Kg 

Operating temp. range 

-20 to +50 degree Celsius 

MR4110

 - 

GSM/GPRS modem  

Tri-band  GSM  900/1800/1900  MHz  GPRS  multi-slot  class 
10 (max 85.6 kbps downlink), mobile station class B, coding 
schemes CS 1-4 

ER4110

 - 

GSM/GPRS/EDGE 
modem  

Quad-band  GSM  850/900/1800/1900  MHz  EDGE  (E-
GPRS)  multi-slot  class  10  (max  236.8  kbps  downlink), 
mobile  station  class  B,  modulation  and  coding  scheme 
MCS1-9 

GPRS  multi-slot  class  12,  mobile  station  class  B,  PBCCH 
support, coding schemes CS 1-4 

HR4110

 - 

GSM/GPRS/EDGE/ 
UMTS/HSDPA/HSUPA 
modem 

Category 5 2Mb HSUPA 
MO 0301: 850 / 1900 / 2100 ( Rx diversity) MHz 
MO 0302: 850 (Rx Diversity) / 1900 (Rx Diversity) / 2100 MHz 
Equalization and Rx Diversity at the same time 

Category  12  (QPSK)  2100  MHz  HSDPA  (max  1.8Mbps 
downlink). 

Quad-band  GSM  850/900/1800/1900  MHz  EDGE  (E-
GPRS)  multi-slot  class  10  (max  236.8  kbps  downlink), 
mobile  station  class  B,  modulation  and  coding  scheme 
MCS1-9 

GPRS  multi-slot  class  12,  mobile  station  class  B,  PBCCH 
support, coding schemes CS 1-4 

USB ports 

Three-port  USB  2.0  Full-speed  Host  (OHCI)  (12  Mbits  per 
second maximum throughput) 

Ethernet interface 

10/100Base-T auto-sensing, auto-MDI/MDX (RJ45) 

Serial interface 

Sync/Async RS232 compatible via 25-way D socket 

Summary of Contents for ER4110

Page 1: ...M M R R 4 4 1 1 1 1 0 0 E E R R 4 4 1 1 1 1 0 0 H H R R 4 4 1 1 1 1 0 0 4000 Series Routers Wireless GSM GPRS EDGE UMTS HSDPA HSUPA Installation Guide ...

Page 2: ... Waste Electrical and Electronic Equipment 2002 96 EC directive has been introduced to ensure that electrical electronic products are recycled using the best available recovery techniques to minimise the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for di...

Page 3: ...Do not attempt to repair the product The unit contains no electronic components that can be serviced or replaced by the user Any attempt to service or repair the unit by the user will void the product warranty 5 The MR4110 ER4110 and HR4110 are designed for indoor use only and should be used in an environment that is suitable for computers and other electronic equipment 6 Ports that are capable of...

Page 4: ...out potential danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failure ...

Page 5: ...n be downloaded from the Digi International website www digi com All models feature 1 x 10 100Base T Ethernet port 1 x RS232 sync async serial port 25 way D 2 x USB 2 0 host ports 2 x SIM card sockets 1 x proprietary expansion port RJ11 GPRS wireless capability The ER4110 also incorporates EDGE wireless capability whilst the HR4110 incorporates EDGE UMTS HSDPA HSUPA capability All models may be pu...

Page 6: ...n 81 HR4110 SSEU 00 81 HR4110 SSEU 01 includes GPS option 81 HR4110 SSEU 02 HR4110 with HSUPA 100V 230VAC 50 60 13A 12V DC 1 5A mains adapter this Installation Guide 2M CAT5 STP shielded twisted pair LAN cable Wireless stub antenna 2 antenna s with the HSUPA option If any item is missing or damaged please contact your supplier You should also make a record of any damage that may have occurred duri...

Page 7: ...s ideal for larger amounts of data or for situations where the speed of data transfer is critical Typical applications include backup for broadband wireline services video transmission etc HSUPA routing is available as an optional upgrade on the HR4110 HSUPA is able to provide a much greater amount of upstream bandwidth than HSDPA In addition the downstream bandwidth is increased too This makes HS...

Page 8: ...ates the type of network connected as described in the 3G Status Indicator Functions table below NET Illuminates steady when a wireless network has been detected SIM Illuminates steady when a valid SIM card is installed in the unit DAT Flashes to indicate that data is being transferred over the wireless network SIGNAL The three indicators labelled SIGNAL illuminate to indicate the GSM signal stren...

Page 9: ...ng user authentication or network login in progress 75ms On 3 s Off Logged on to network monitoring control channels and user interactions no call in progress 75ms On 75ms Off 75ms On 3s Off One or more GPRS contexts activated Flashing LED is On when data packets were exchanged in GPRS online mode during the last second On Connected to remote party or exchange of parameters while setting up or dis...

Page 10: ...ments it should not be used with a longer cable GPRS EDGE This SMA connector is used to fit the wireless antenna supplied with the unit A range of alternative antennas are available for purchase separately LAN The socket labelled LAN is used to connect the unit to a 10 100Base T LAN using the 2 metre STP Shielded Twisted Pair cable supplied or a suitable alternative This port is auto sensing for s...

Page 11: ...a range of suitable aerials Important Note If you are going to be using the Sar OS Connection Wizard to configure the unit s Ethernet port and also connect it to your GSM 3G network skip this section and proceed to Configuration Step 1 Installing the SIM card s The router incorporates two separate SIM card holders so that if your application demands it you may install SIM cards for two different n...

Page 12: ...nal device connect the 25 way D plug on the serial cable provided to the SERIAL connector on the rear of the unit Connect the other end of the cable 9 way D socket to the terminal If the serial connector on the terminal is not a 9 way D plug you will need a suitable adapter Step 5 Connecting the GPS antenna if applicable If you have purchased the router with the GPS option fitted this connector is...

Page 13: ...ult IP address for the LAN 0 port is 192 168 0 99 with a Class C subnet 255 255 255 0 Setting your PC s IP address to one on the same subnet 192 168 0 will enable you to connect to the unit s Web interface You will then be able to configure the unit manually Step 1 Install the Connection Wizard Download the connection wizard from the Digi website and install the software on your PC Step 2 Run the ...

Page 14: ...class B modulation and coding scheme MCS1 9 GPRS multi slot class 12 mobile station class B PBCCH support coding schemes CS 1 4 HR4110 GSM GPRS EDGE UMTS HSDPA HSUPA modem Category 5 2Mb HSUPA MO 0301 850 1900 2100 Rx diversity MHz MO 0302 850 Rx Diversity 1900 Rx Diversity 2100 MHz Equalization and Rx Diversity at the same time Category 12 QPSK 2100 MHz HSDPA max 1 8Mbps downlink Quad band GSM 85...

Page 15: ...MR4110 ER4110 HR4110 Installation Guide 14 GPS optional Fastrax iTrax03 02 12 channel 153 dBm tracking sensitivity ...

Page 16: ... 01 MR4110 with GPS 81 ER4110 SSEU 00 81 ER4110 SSEU 01 ER4110 with GPS 81 HR4110 SSEU 00 81 HR4110 SSEU 01 HR4110 with GPS 81 HR4110 SSEU 02 HR4110 with HSUPA conform s to the relevant harmonised standards EN60950 1 A11 2004 Health Safety EN301489 7 v1 3 1 EMC EN301511 v9 0 2 RF spectrum efficiency following the provisions of Council Directive 1999 5 EC on radio equipment and telecommunications t...

Reviews: