     SECTION 6: OPERATION, CONTINUED

On/Off

Temperature

Delayed Start Time

Sauna Length

Light

Fan

Memory / User 1

Memory / User 2

Memory / User 3

Memory / User 4

Control Setup:

This setup has 

6 different menus.

To escape from this 

Setup Menus

, press the 

On/Off

 button or the device will

 automatically exit 

the menu in 

approx.

 4 seconds.

To enter

 the 

Setup Menu

 

p

ress 

PROG/OK

 button and hold down for approx. 

3 seconds

 until the following 

appears in the display:

 

 

MENU 1

 

 

TIME: 12:00  

Setting the Clock: 

Press the up arrow and hold down: The minutes and hours will begin to change. When 

the hour reads the correct time, release the up arrow key and enter minutes by repeatedly pressing the arrow 
key for each minute. Press 

PROG/OK 

 to save the time in memory.

Next will display:

  MENU 2
 

 

LANGUAGE: ENGLISH 

 

Setting Language:

 

Press the up or down arrow key repeatedly until the language you desire appears in the 

display. Press 

PROG/OK

 to save in the Language in memory. 

Increase

Decrease

Summary of Contents for Digi II 4.5

Page 1: ...l and benches Replace wood surfaces which show any signs of deterioration The heater gets extremely hot during operation and should not be touched or burns may result Minors should be adequately super...

Page 2: ...M 1 MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL Screws Use the long screws in the upper holes of the mounting bracket 11 57 8 11 B Screws Table 1 K A D High Limit Control 6...

Page 3: ...and reinstall reusable rocks Follow the directions below for placement and the 1 Put smaller rocks in first around the outer perimeter of the heating chamber 2 Completely fill all four sections front...

Page 4: ...AWG N Gr 1 208 28 8 2 8AWG N Gr 1 240 25 2 8AWG N Gr 3 208 16 7 3 12 AWG N Gr 3 240 14 4 3 12 AWG N Gr 1 208 38 5 2 8AWG N Gr 1 240 33 3 2 8AWG N Gr 3 208 22 2 3 10 AWG N Gr 3 240 19 2 3 10 AWG N Gr 2...

Page 5: ...e maximum control wire length would be 90ft The sensor should be mounted over the heater 2 from the ceiling and connected to the circuit board on terminals 2 and 3 See Diagram 1 Control Overview Alarm...

Page 6: ...r 1714 800 1705 8 0 2xAWG 8 N Gr 3xAWG 10 N Gr 1 2 3 4 5 6 Gr Gr N T1 T2 T3 Gr Gr N T1 T2 Heater The electrical installation must be made by a licensed electrician in accordance with local regulations...

Page 7: ...ess PROG OK button and hold down for approx 3 seconds until the following appears in the display MENU 1 TIME 12 00 Setting the Clock Press the up arrow and hold down The minutes and hours will begin t...

Page 8: ...ext will display MENU 5 CLOCK 24 h Using the arrow keys select a 12 or 24 hour clock If a 12 hour clock is selected AM or PM will appear in the display after the time Press PROG OK to save the setting...

Page 9: ...ing will appear in the display start time sauna length and temperature 17 30 01 00 The maximum the timer will allow the heater to operate is 60 minutes 90C Press Time Delay button and the hours and mi...

Page 10: ...Sauna depending on what delay mode is selected 15 00 is the current time and 17 30 is the time the room is ready to enter Daily Operations of Memory User buttons Press ON OFF and the greeting appears...

Page 11: ...ress when completely dry and perspiration has stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks Use only one dipper full approx cup at a time a...