Error Messages 

 

Display 

Possible Cause 

Solution 

Press “POWER” no display 

The 230V/AC power supply 

not working or Re-

chargeable battery voltage 

Check the power supply or 

battery and power switch 

One section of LED display 

no light 

The LED display is not good 

in condition 

To replace LED display 

The display reading not 

stable 

To check the flatform 

structure 

To open the platform 

structure and clean the 

structure 

The scale can not do 

calibration 

To check the calibration 
jumper (put to “ON” position) 

To open casing and palce 

the cal jumper ON position 

The scale is not accurate 

The Loadcell is not good in 

condition 

To replace the new Loadcell 

Operation Mode 

Open the casing , switch the jumper ( JP1 ) to “ OFF ” position. 

The function will be as follow: 

 

 

 

 

Press 

“T”

 and 

hold for 1.5 

seconds 

  

CAL 

 Press M 

    OFF 

 Press M 

 Press M 

 Press M 

 Press M 

 Press M 

    BP 

    LO 

    OK 

    HI 

    EXIT 

Summary of Contents for DI-28SS

Page 1: ...iko Co Ltd Head office 13 12 Kugahara 5 chome Ohta Ku Tokyo 146 8580 Japan TEL 81 3 3752 2131 FAX 81 3 3752 2801 Ohsaki office 2 3 13 Ohsaki Shinagawa Ku Tokyo 141 8566 Japan TEL 81 3 5496 7600 FAX 81 3 5496 7620 http www digisystem com email info hq digi co jp ...

Page 2: ...Page 2 of 6 Contents Overview 2 Features 2 Description of display 4 Key switch function 4 Function setting 5 Error messages 6 Operation mode 6 ...

Page 3: ... 20 times second 3 Internal resolution 1 300 000 4 Display resolution 1 1000 1 30 000 division 5 Non linearity 0 016 F S 6 Rated Output 0 20mV 7 Excitation Voltage _DC5V Analog up to 4 x 350Ω load cell 8 Power supply DC6V 4Ah re charge battery or AC230V power supply 9 Display 6 digits LED display and height 25mm LED 10 LED indicate G W N W tare zero ct oz lb kg 11 Power consumption 1W 12 Operating...

Page 4: ...t The weight is over the preset value OK Pass limit The weight I between HI LO preset value LQ Low limit The weight is under the preset value Switch bottom function 1 Switches Power On Off i Press I once the display show a self test and come to Zero on the screen Each LED will display 0 to 9 in sequence during the self test ii Press and hold I for 3 0 second the display will shut down automaticall...

Page 5: ... Press to choose On or OFF for buzzer sound or not sound 3 Press M the display show L XX X Press to select a new value for weight under the limit LO 4 Press M the display show 0 XX X Press to select a new value for weight between the HI LO limit OK 5 Press M the display show H XX X Press to select a new value for weight over the limit HI 6 Press M the display show 08 09 10 Mean is year month day 0...

Page 6: ... stable To check the flatform structure To open the platform structure and clean the structure The scale can not do calibration To check the calibration jumper put to ON position To open casing and palce the cal jumper ON position The scale is not accurate The Loadcell is not good in condition To replace the new Loadcell Operation Mode Open the casing switch the jumper JP1 to OFF position The func...

Reviews: