Set
% Weight:
Set Point 1 : Weight (See Note Below)
ZERO 5: RECOMPUTATION
LB
SCALE 3
Set Point 2 : % Weight (See Note Below)
TARE 6: MEMORY 10: BATTERY LOW 14: SCALE 4
Set
0 and 1 of
7 to 01 3: GROSS 7: PROG
SCALE 1
IN
4: INSUFFICIENT
12: SCALE 2
OUT
OPERATION
DISPLAY
ND CATOF
REMARKS
OPERATION
WEIGHT
UNIT
WEIGHT
QUANTITY
1 2 3 4 5 6 7
8 9 1
0
1
1
2
1
3
1
4
1
5
1
6
1
0.0000
0
0
•
•
•
*
Display in the weighing mode
[MODE]
ProG
C
0
•
Press the [MODE] key to go into the
programming mode.
3
0.
*
•
Press
key to go into Set Point
Programming Mode.
4
3.0000
Enter
Weight value for Set Point
1 using the [Numeric] keys
depending on the capacity of the
scale. Please see the note below.
5
0.
•
•
Press the
key to program Set
Point 2.
6
2
50.75
•
Enter the
value for Set
Point 2 using [Numeric]
Please see the note below.
7
M
ProG
Pressing the
key exits from the
Set Point Programming mode, but
remains in the Programming
8
[MODE]
0.0000
0
0
•
•
*
Pressing the
key exits from
Programming mode and returns to
Weighing mode.
Note : Set Point 1 : Must be a weight value depending on the capacity of the scale.
Set Point 2 : Percentage value up to 999%, but set according to Set Point 1 value.
Ex: Suppose Set Point 1=5.0000 (capacity of the scale),
Set Point 2 cannot be set more than
OPERATION MANUALREV03.DOC