18
6.0. PROGRAMMING MODE:
6.1.
Set Point Programming :
6.1.1.
Set Point Programming by % Quantity
Set Point 1 : Quantity (See Note Below) , Set Point 2 : % Quantity (See Note Below)
Set bit 0 and 1 of Spec 7 to 00
1
Display in the weighing mode
2
Press the
[MODE]
key to go into the programming mode.
3
Press
[
+
+
+
+
]
key to go into Set Point Programming Mode.
4
Enter the Quantity for Set Point 1 using the
[Numeric]
keys. Example type
[1][0][0][0][0]
5
Press
[
+
+
+
+
]
key to go to Set Point 2.
6
Enter the new Set Point 2 value using the
[Numeric]
keys. Example type
[7][5]
7
Pressing the
[
+
+
+
+
]
key exits from the Set Point Programming mode, but remains in the
Programming mode.
8
Pressing the
[MODE]
key exits from Programming mode and returns to Weighing mode.
NOTE:
Using the
[C]
key clears the key entry.
Note :
Set Point 1 : Must be a quantity value up to 999999.
Set Point 2 : Percentage value up to 999%, but set according to Set Point 1 value. Ex: Suppose
Set Point 1=999999, Set Point 2 cannot be set more than 100%.
6.1.2. Set Point Programming by % Weight
Set Point 1 : Weight (See Note Below), Set Point 2 : Weight (See Note Below)
Set bit 0 and 1 of Spec 7 to 01
1
Display in the weighing mode
2
Press the
[MODE]
key to go into the programming mode.
3
Press
[
+
+
+
+
]
key to go into Set Point Programming Mode.
4
Enter the Weight value for Set Point 1 using the
[Numeric]
keys depending on the capacity of the
scale. Please see the note below. Example type
[3][.][0][0][0][0]
5
Press the
[
+
+
+
+
]
key to program Set Point 2.
6
Enter the percentage value for Set Point 2 using
[Numeric]
keys. Please see the note below.
[7][5]
7
Pressing the
[
+
+
+
+
]
key exits from the Set Point Programming mode, but remains in the Programming
mode.
8
Pressing the
[MODE]
key exits from Programming mode and returns to Weighing mode.
Note :
Set Point 1 : Must be a weight value depending on the capacity of the scale.
Set Point 2 : Percentage value up to 999%, but set according to Set Point 1 value. Ex: Suppose Set
Point 1=5.0000 (capacity of the scale), Set Point 2 cannot be set more than 100%.