Revision history—90000540

Revision

Date

Description

H

November
2022

Updated the

Immunity

values. See

Certifications

.

G

October
2015

In

Specifications

>

Digi Connect Wi-SP

, lowered transmit power for

the Digi Connect Wi-ME 7520 radio used in the Digi Connect Wi-SP from
16 dBm to 14 dBm to be lowered to comply with new European Wi-Fi
requirements.
Changed

Programming considerations

>

GPIO

section to minimize

content and state that GPIO control is available as GPIOxx if using the
Digi Connect SP and Digi Connect Wi-SP with NET+OS firmware, with a
reference to NET+OS and hardware reference information.
Applied new front cover format.
Moved Change Log to front matter.
Applied new documentation template.

F

8/12/2011

Changed barrel connector to locking barrel connector in the “Power
Jack” section of Chapter 1. Added Digi contact information.

E

12/28/2006

Digi branding changes.

D

8/12/2005

Updated Antenna drawing. Changed antenna restriction in North
America. Added product weight.

Trademarks and copyright

Digi, Digi International, and the Digi logo are trademarks or registered trademarks in the United
States and other countries worldwide. All other trademarks mentioned in this document are the
property of their respective owners.

© 2022 Digi International Inc. All rights reserved.

Disclaimers

Information in this document is subject to change without notice and does not represent a
commitment on the part of Digi International. Digi provides this document “as is,” without warranty of
any kind, expressed or implied, including, but not limited to, the implied warranties of fitness or
merchantability for a particular purpose. Digi may make improvements and/or changes in this manual
or in the product(s) and/or the program(s) described in this manual at any time.

Warranty

To view product warranty information, go to the following website:

www.digi.com/howtobuy/terms

Customer support

Gather support information:

Before contacting Digi technical support for help, gather the following

information:

Summary of Contents for Connect Wi-SP

Page 1: ...Digi Connect SP and Digi Connect Wi SP Digi Connect Family Hardware Reference...

Page 2: ...ing changes D 8 12 2005 Updated Antenna drawing Changed antenna restriction in North America Added product weight Trademarks and copyright Digi Digi International and the Digi logo are trademarks or r...

Page 3: ...n of issue Steps to reproduce Contact Digi technical support Digi offers multiple technical support plans and service packages Contact us at 1 952 912 3444 or visit us at www digi com support Feedback...

Page 4: ...Purpose I O GPIO control 13 LEDs 13 Memory 14 Reset button 14 Specifications Network interfaces 15 Serial interface 15 Data rates bps 15 Flow control options 16 Environmental specifications 16 Power r...

Page 5: ...SP and Digi Connect Wi SP Hardware Reference 5 Labeling requirements FCC 15 19 23 Modifications FCC 15 21 23 Cables FCC 15 27 23 Innovation Science and Economic Development Canada 23 International EMC...

Page 6: ...SP platform using the NET OS operating system and tools Related documentation See the Digi website for the following related documentation n See the NS7520 Hardware Reference manual for information on...

Page 7: ...SP and Digi Connect Wi SP connectors LEDs and switches MEI switches and the Reset button are in the same location for both the Digi Connect SP and Digi Connect Wi SP Digi Connect SP hardware Digi Conn...

Page 8: ...is software programmable The default is that this LED indicates power and is therefore always on See LEDs for more information Link Green Network link status n On unit is associated with an access po...

Page 9: ...with 5dB loss to separate the antenna from the product CAUTION This FCC Part 15 Class A radio device operates on a non interference basis with other devices operating at this frequency when using the...

Page 10: ...Pin EIA 232 EIA 422 485 Full Duplex EIA 485 Half Duplex 1 DCD CTS Not used 2 RXD RXD RXD 3 TXD TXD TXD 4 DTR RTS Not used 5 GND GND GND 6 DSR RXD RXD 7 RTS RTS Not used 8 CTS CTS Not used 9 NA TXD TX...

Page 11: ...i SP Hardware Reference 11 Digi Connect SP JTAG debugger connector JTAG debugger pin assignments Pin Assignment Pin1 VCC Pin 2 GND Pin 3 TRST Pin 4 GND Pin 5 TDI Pin 6 GND Pin 7 TMS Pin 8 GND Pin 9 TC...

Page 12: ...arrel connector that accepts 9 to 30 VDC 5 The jack is labeled as P11 on the development board Power jack polarity Contact Polarity Center 9 to 30 VDC Outer Ground The following figure schematically r...

Page 13: ...development kit supplies software to control the LEDs This behavior can often be modified by manipulating the LED table in the BSP code In the development kit see the file gpio c for details As with...

Page 14: ...rolled by chip select 1 located at 0x00000000 in the processor address space and aliased at 0x04000000 and 0x08000000 The application program EOS is loaded at address 0x08080000 Reset button Digi Conn...

Page 15: ...Modulation CCK 11 5 Mbps DQPSK 2 Mbps DBPSK 1 Mbps n Transmit power 14 dBm typical n Receive sensitivity l 1Mbps 92 dBm l 2Mbps 89 dBm l 5 5Mbps 87 dBm l 11Mbps 82 dBm n Antenna connector RP SMA n 10...

Page 16: ...ust be powered by a Listed LPS or Class II power supply rated 9 30 VDC 0 37 A minimum Mechanical specifications Digi Connect SP n Length 3 876 inches 9 846 cm n Width 1 680 inches 4 267 cm n Height 0...

Page 17: ...gnal strength is as expected 0 Antenna details Antenna Description Dipole Desktop Part number DC ANT 24DP DC ANT 24DT Frequency 2 4 2 5 GHz 2 4 2 5 GHz Power Output 2 W 1 W DB Gain 2 dBi 1 8 dBi VSWR...

Page 18: ...Specifications Antenna information Digi Connect SP and Digi Connect Wi SP Hardware Reference 18 Desktop antenna dimensions...

Page 19: ...Specifications Antenna information Digi Connect SP and Digi Connect Wi SP Hardware Reference 19 Dipole antenna dimensions...

Page 20: ...Specifications Overlay specifications Digi Connect SP and Digi Connect Wi SP Hardware Reference 20 Overlay specifications Digi Connect SP...

Page 21: ...Specifications Overlay specifications Digi Connect SP and Digi Connect Wi SP Hardware Reference 21 Digi Connect Wi SP...

Page 22: ...s for humans as called out in RSS 102 It is exempt from RF evaluation based on its operating frequency of 2400 MHz and effective radiated power of less than 400 milliwatts This would be less than the...

Page 23: ...plies with Part 15 of FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including...

Page 24: ...following standards Standards Digi Connect SP Digi Connect Wi SP Emissions AS NZS 3548 AS NZS 3548 CISPR 22 ICES 003 IC RSS 210 IC 1846A 50M1312 EN 55022 ICES 003 EN 61000 3 2 EN 55022 EN 61000 3 3 E...

Reviews: