Configure the device using the ConnectPort LTS web interface
Administration
Digi ConnectPort LTS User Guide
124
Update the BIOS code
You can only update the BIOS code through the boot loader. To update BIOS code, see
.
Important
Before uploading the firmware, read the firmware Release Notes to see if you need to
update the BIOS code before updating the firmware.
Factory default settings
Restoring a ConnectPort LTS device to its factory default settings clears all current configuration
settings with some exceptions. See the following topics for more information:
n
Settings cleared and retained during a factory reset
n
There are several ways to reset the device configuration of a ConnectPort LTS product to the factory
default settings:
n
From the
using the Restore Factory Defaults operation
This method is the best way to reset the configuration, because you can back up the settings
using the Backup/Restore operation. The Backup/Restore operation provides a means to
restore the configuration after the configuration issues have been resolved. See
factory settings on a ConnectPort LTS product from the web interface
for more information.
n
From the command-line interface, using the
boot
or
revert
commands
n
Using the reset button on the ConnectPort LTS device
Use this method if you cannot access the device from a web browser. The location of the reset
button may vary. See
Reset the factory settings on a ConnectPort LTS product using the Reset
for more information.
n
From the LCD display under
Miscellaneous
Settings cleared and retained during a factory reset
A factory reset does not delete files uploaded to the File Management page. See
for more information.
n
Restore
: Returns the configured settings on the Digi device to the factory defaults.
n
Keep network settings
: Select this check box to retain the IP address settings.
n
Restore Only Serial Port Settings
: Select this check box to restore only the serial settings to
their factory defaults. The other configuration settings remain as-is.
Reset the factory settings on a ConnectPort LTS product from the web interface
To reset the factory settings on the ConnectPort LTS device from the web interface:
1. Create a backup copy of the configuration using the Backup/Restore operation. See
for more information.
2. Select
Administration
>
Factory Default Settings
. The Factory Default Settings page appears.