Menus and Calibration
D3895-US Rev A
EZ2500 User’s Manual
15
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
ANALOG HIGH
WEIGHT
(HIGHWT)
242
Enter analog weight value to
equal 20mA or 5 volts
ANALOG SELECT
(ANAOUT)
243
Select 0-5V,4-20ma or 0-20ma
output
MENU 3. SCALE CALIBRATION SETTINGS
DISPLAY UNIT
(lb-kg)
301
.01,.02,.05,.1,.2,.5,1,2,5,
10
,20, 50,100
Select display count size of
weigh values.
CAPACITY
(cap)
303
LB
/KG
Display pounds -lb or
kilograms -kg
WM1 ADJUST 1
(wmaI-I)
304 40000
Enter MAXIMUM weight
measurable on scale.
MENU 4. PRESET, BATCHING & ROTATION COUNTER FEATURES
Does not apply to 2500 indicator
CALIBRATION
DEAD WEIGHT
CAL
(CAL)
802
Calibration method using
weights
SETUP NUMBER
(SETUP)
871
Quick entry method selects
weigh method 1-4lbs, 5-8 kg,
gain 1-9, display counts 1-9
and capacity *1000
CALIBRATION
NUMBER
(CAL)
872
Weight displayed at 0.4mV/V
for these load cells