![Digi-Pas DWL5000XY Installation And Operation Manuallines Download Page 12](http://html.mh-extra.com/html/digi-pas/dwl5000xy/dwl5000xy_installation-and-operation-manuallines_2496732012.webp)
Digi-Pas
®
© 2018 Digipas Technologies Inc. All Rights Reserved.
www.digipas.com
Page 7
DWL-5x000XY DATA SHEET
3.2.
Configuration of Sensor Module(s) with Control Box
3.2.1.
Materials for the Configuration
•
1 × DWL5000XY, DWL5500XY or DWL5800XY tilt sensor module secured with sensor
cord
•
1 × 12-20VDC Power Source
• 1 × DigiPas DWL5x00XYcontrol box
• 1 × USB cable or 1 × RS232 converter or 1 × RS485 converter In this example,
EasySync Converter (Model number: ES-U-3001-M) is used.
3.2.2.
Configuration Setup Procedure
1. Secure the sensor cord with tilt sensor module as stated in 2.1 Securing Tilt Sensor Module
with Sensor Cord.
2.
Connect the sensor cord to the sensor input on the DigiPas DWL5x00XYcontrol box as
shown in Figure 12.
3. Source in regulated 12VDC to 20VDC to the power supply input.
4.
The Power LED (PWR) of the control box lights in orange colour. Once the initialization
between the sensor module and the control box is completed, the Power LED turns to
yellow. The Sensor LED (SEN 1, SEN 2, SEN 3, SEN 4) on respective sensor lights up in green
colour. If the connection between the tilt sensor module and control box is lost, the
Power LED lights up in red.
Figure 12. Overview of the Control Box