4
PDI 5-30 Service and Repair Manual - January 2012 - PM-000086
SINGLE & DOUBLE PLANETARY AUGER DRIVES
This manual is intended to be used by persons with reasonably mechanical skills and understanding of mechanical components.
This manual will assist in the disassembly and assembly of the above model Planetary Auger Drives. Item numbers, indicated in pa-rentheses
throughout this manual, refer to the exploded parts breakdown drawing. Individual customer specifications (mounting hood, output shaft etc.) may
vary from exploded drawing and standard part numbers shown. Contact
Digga Australia
for enquiries.
For any spare or replacement parts, contact
Digga Service and Spares or a local Digga representative
. For identification purposes always try
to have available the auger drive unit type and serial number. This information may be necessary for verification of any component part numbers.
Component part numbers and/or manufacturing gear set numbers may be stamped on individual parts. This information may also be helpful in
identifying replacement components.
LUBRICATION & MAINTENANCE
Change the gear oil after 6 months or 80 hours of moderate operation.
Oil should be changed at yearly intervals thereafter. All gearboxes
require
EPG, ISO 320
grade gear oil or equivalent for lubrication. It is also recommended that unit be partially disassembled to inspect gears and
bearings at 2 year intervals.
PD UNIT
OIL QUANTITY - LTRS - (US QUARTS)
PDI 5-7
1.45 (1.53)
PDI 9-12
2.5 (2.64)
PDI 13-16
3.2 (3.38)
PDI 20 - 30
4.8 (5.1)
NOTE:
HEAVY DUTY OPERATION. CHANGE THE GEAR OIL AFTER 3 MONTHS OR 40 HOURS OF OPERATION. CHANGE OIL
EVERY 6 MONTHS OR 500 HOURS THEREAFTER. INSPECT GEARS AND BEARINGS ANNUALLY.