15. 

ProBLEM

PoSSIBLE CAUSE

rEASon/SoLUTIon

No reading on the ammeter. Charger is not plugged in.

No power at the receptacle.

Clips are not making a good 

connection to the battery.

Connections are reversed.

Battery is defective (will not 

accept a charge).

2 amp charge rate is being 

used.

Plug the charger into an AC 

outlet.

Check for open fuse or 

circuit breaker supplying AC 

outlet.

Check for poor connection 

to battery and frame. Make 

sure connection points are 

clean. Rock clips back and 

forth for a better connection.

Unplug the charger and 

reverse the clips.

Have battery checked.

Ammeter may show no 

activity at the 2A charge 

rate.

Ammeter reading stays 

high.

Battery is severely 

discharged.

Wrong battery voltage.

Continue charging battery 

for two more hours. If 

problem continues have the 

battery checked.

Verify the voltage of the 

battery is 12 volts.

Charger will not turn on 

when properly connected.

AC outlet is dead.

Poor electrical connection.

Check for open fuse or 

circuit breaker supplying AC 

outlet.

Check power cord and 

extension cord for loose 

fitting plug.

The battery is connected 

and the charger is on, but is 

not charging.

Clips are not making a good 

connection.

Check for poor connection 

at battery and frame. Make 

sure connecting points are 

clean. Rock clips back and 

forth for a better connection.

The measured current is 

much lower than what was 

selected.

The charger reached the 

maximum voltage and is 

reducing the current.

No problem, this is a normal 

condition.

Ammeter reads less than 

selected charge rate when 

charging a discharged 

battery

Extension cord is too long or 

wire gauge is too small.

Weak cell or sulfated plate 

in battery.

Battery is only partially 

discharged.

Use a shorter or heavier 

gauge extension cord.

A sulfated battery will 

eventually take a normal 

charge if left connected. If 

the battery will not take a 

charge, have it checked.

Continue to charge the 

battery.

Summary of Contents for DH-6M

Page 1: ...anagement Corporation Hoffman Estates IL 60179 U S A OPERATOR S MANUAL Manual del usuario Read all Safety Rules and Operating Instructions and follow them with each use of this product ATENCI N Lea to...

Page 2: ......

Page 3: ...ORAGE INSTRUCTIONS 9 TROUBLESHOOTING 10 BEFORE RETURNING FOR REPAIRS 11 DieHard ONE Year Full Warranty When operated and maintained according to all supplied instructions if this DieHard product fails...

Page 4: ...el manejo y almacenamiento 21 LOCALIZACI N Y SOLUCI N DE PROBLEMAS 21 ANTES DE DEVOLVER A REPARACIONES 23 UN A O DE GARANT A TOTAL EN DIEHARD Cuando se opere o maneje con las debidas precauciones de...

Page 5: ...or serious injury to the operator or bystanders Indicates a potentially hazardous situation which if not avoided could result in death or serious injury to the operator or bystanders Indicates a poten...

Page 6: ...risk of electric shock unplug the charger from the outlet before 1 6 attempting any maintenance or cleaning Simply turning off the controls will not reduce this risk Do not operate the charger with a...

Page 7: ...t and cause injury to persons and damage to property NEVER charge a frozen battery 2 5 NEVER overcharge a battery 2 6 Consider having someone close enough by to come to your aid when you work 2 7 near...

Page 8: ...make sure that the output voltage selector switch is set to the correct voltage If the charger has an adjustable charge rate charge the battery in the lowest rate first Make sure that the charger cab...

Page 9: ...o the chassis see step 6 6 For a negative grounded vehicle connect the POSITIVE RED clip from the 6 5 battery charger to the POSITIVE POS P ungrounded post of the battery Connect the NEGATIVE BLACK cl...

Page 10: ...ble Do not face the battery when making the final connection 7 5 Connect charger AC supply cord to electrical outlet 7 6 When disconnecting the charger always do so in the reverse order of the 7 7 con...

Page 11: ...in amps that is being drawn by the battery As a battery takes on a charge it draws less current from the charger Correspondingly the meter will show less current being drawn by the battery When the c...

Page 12: ...l take to bring the battery to full charge 2 See the Calculating Charge Time section Select the appropriate settings for your battery 3 Connect the AC power following the precautions listed in section...

Page 13: ...s and the charger case Ensure that all of the charger components are in place and in good working 13 3 condition including the plastic boots on the battery clips Servicing does not require opening the...

Page 14: ...is 12 volts Charger will not turn on when properly connected AC outlet is dead Poor electrical connection Check for open fuse or circuit breaker supplying AC outlet Check power cord and extension cor...

Page 15: ...s is a normal condition Have charger checked by a qualified technician BEFORE RETURNING FOR REPAIRS 16 When a charging problem arises make certain that the battery is capable of 16 1 accepting a norma...

Page 16: ...ededor Indica una situaci n potencialmente riesgoso que si no se evita podr a resultar o de serios perjuicios al operador o personas alrededor Indica una situaci n potencialmente peligrosa que de no e...

Page 17: ...rgador El alargador se encuentre correctamente conectado y en buenas condiciones el ctricas El tama o del cable sea lo suficientemente extenso para el amperaje en C A del cargador como se especifica e...

Page 18: ...uito lo suficientemente elevada como para soldar un anillo o provocar efectos similares sobre el metal causando una quemadura de gravedad Tenga especial cuidado para reducir el riesgo de dejar caer un...

Page 19: ...cto con sus ojos nariz y boca Utilice bicarbonato de sodio y agua para neutralizar el cido de la bater a y ayudar a eliminar la corrosi n producida por aire No toque sus ojos nariz o boca Agregue agua...

Page 20: ...r en un rea cerrada o restrinja la ventilaci n en 4 5 cualquier forma PRECAUCIONES DE CONEXI N EN CC 5 Conecte y desconecte los ganchos de salida C C s lo despu s de haber 5 1 establecido todos los in...

Page 21: ...ater a No conecte el gancho al carburador l neas de combustible o cuerpos met licos Conecte a una pieza met lica de calibre grueso del marco o del bloque motor En un veh culo con descarga a tierra por...

Page 22: ...to con tensi n nominal de 120 V y posee un enchufe con descarga a tierra que luce como el enchufe ilustrado El cargador debe poseer una descarga a tierra para reducir el riesgo de descargas el ctricas...

Page 23: ...de carga Se encuentra establecido en escala para utilizar solamente con el ndice de carga de 6 amperios Para el ndice de carga de 2 amperios utilice el tri ngulo El porcentaje de carga se basa en la c...

Page 24: ...ceso de carga y detenerlo cuando la bater a se encuentre cargada Dejar de llevar esto a cabo podr a provocar da os en la bater a u ocasionar otros da os en la propiedad o lesiones personales C LCULO D...

Page 25: ...jete una con otra ni al metal 14 3 o a los cables Si el cargador se mueve alrededor del taller o se transporta a otra localidad 14 4 trate de evitar prevenir da o a los cables pinzas y al cargador El...

Page 26: ...o carga Los ganchos no se encuentran bien conectados Controle la posible presencia de una conexi n defectuosa a la bater a o al bastidor Aseg rese de que los puntos de conexi n est n limpios Mueva los...

Page 27: ...ficador de salida cortocircuitado provocan un zumbido No es un problema es una situaci n habitual Haga revisar el cargador por un t cnico capacitado ANTES DE DEVOLVER A REPARACIONES 16 Cuando surja un...

Reviews: