background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

WARNING! 

  

To reduce the risk of injury or death it is important to closely follow all of the following 

instructions. Incorrect installation or inappropriate use may cause serious personal injury. 
 
This  installation  manual  and  safety  instructions  are  an  integral  part  of  the  product  and  must  be 
supplied  to  the  user.  These  instructions  should  be  retained  by  the  owner  and/or  operator  of  the 
gate. 

 

This product has been designed and constructed exclusively for the use indicated in this manual. 
Any inappropriate use of this product may result in damage to the product and/or personal injury. 

 

To ensure proper functioning of the product and personal safety only use the mounting equipment 
supplied and the spare parts and accessories supplied by the manufacturer. 
 
Do  not  install  this  equipment  in  an  easily  flammable  environment.  The  presence  of  inflammable 
gases or smoke is a serious threat to personal safety.  

 

The automatism has an anti-crush safety device. However, other safety devices should be installed, 
such  as  photocells,  sensitive  bands,  etc,  that  allow  avoiding  the  dangers  derived  from  moving 
mechanical actions (crushing, dragging, shearing). 
 
In  addition  to  the  above  mentioned  safety  devices  it  is  also  necessary  to  install  at  least  one  light 
signal as well as a printed notice fixed to the gate. 

 

The  installation  of  this  equipment,  the  electrical  connections  and  maintenance  of  the  equipment 
may  only  be  carried  out  by  qualified  technicians.    Failure  to  meet  this  requirement  may  cause 
severe injury and/or death, for which the manufacturer will not be held responsible. 

 

For protection against electrical overload or short circuit, always install a 0.03 amp differential and a 
thermal magnetic switch with a contact aperture of at least 3mm  
 
This equipment must be earthed with a yellow/ green cable, connected to the earth terminal in the 
junction box. The safety of this product is only guaranteed if the equipment is properly earthed.  

 

Before operating this product you must ensure that all connections have been properly made, that 
the  safety  devices  are  properly  working  and  that  the  pressure  force  is  adjusted  to  the  minimum 
according  to  regulations  regarding  automatic  doors  (EU  Directive  89/392  and  EN  12453  y  EN 
12445 norms). 

 

Before installing this equipment, ensure that the structure of the gate is strong enough and properly 
balanced.  The  gates  must  work  freely  in  both  directions  and  have  no  friction  points  before  the 
automatic operator is installed

.

 

 

SAFETY INSTRUCTIONS FOR THE USER 

 

In  the  event  that  a  malfunction  in  the  equipment,  contact  a  qualified  technician.  DO  NOT  try  to  repair  the 
equipment yourself

 

Do  not  allow  children  or  pets  near  the  gate.  Never  allow  children  to  play  with  the  gate  controls.  Keep  the 
remote control in a safe place, out of reach of children and unauthorized persons

.  

 

In  the  event  of  a  power  cut  or  emergency,  you  must  learn  how  to  use  the  manual  release  mechanism 
according to the procedures found in this installation manual 

 

Keep these safety instructions in a safe place. Make sure that all persons who use the gates or who may be 
near the gates when they operate are aware of the dangers associated with automatic opening gates 
 
If  you  sell  or  rent  the  property  with  this  equipment  installed,  give  the  new  owner  or  tenant  a  copy  of  these 
safety instructions  

 

Summary of Contents for ELIOT 800AC

Page 1: ...INSTRUCTION MANUAL SLIDING GATE AUTOMATION ELIOT Ed1 14 12 09 English ...

Page 2: ...facturer will not be held responsible For protection against electrical overload or short circuit always install a 0 03 amp differential and a thermal magnetic switch with a contact aperture of at least 3mm This equipment must be earthed with a yellow green cable connected to the earth terminal in the junction box The safety of this product is only guaranteed if the equipment is properly earthed B...

Page 3: ...RK POWER SUPPLY 230 Vac 50Hz MOTOR POWER SUPPLY 230 Vac ABSORBED POWER 422W CONSUMPTION 1 85 A CONDENSER 10µf THERMAL POWER 130ºC ENCODER Optical REVOLUTIONES OF ELECTRIC MOTOR 1450 Rpm GATE SPEED 10 8 m min TORQUE 40 Nm LUBRICATION GRASA NLGI 0 LIMIT SWITCHES Mechanical SERVICE TEMPERATURE 20ºC to 70ºC LEVEL OF PROTECTION IP54 WORK FACTOR 40 WEIGHT 11 5Kg COG MODULE M4 MAX WEIGHT OF GATE 800Kg ...

Page 4: ...r motor 3 Rack M4 4 Nut M10 5 Washer M10 6 Leveling Nut 10 7 Base Plate 8 Rod M10x150 The B elevation indicates the distance from the centre of the rack to the door The A elevation indicates the distance between the edge of the base plate and the door B 30 ...

Page 5: ...AUTOMATISM INSTALLATION ...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ... place 13 Position the motor parallel to the door 14 Fix the motor 15 Unblock the motor using the unblocking lever 16 Mount the rack with the screws and separators previously It is advised that the screws be fixed to the upper part of the mounting hole to allow the rack to be lifted in the future in the event of the door or floor guide suffering horizontal movements 17 Rest the first part of the r...

Page 10: ...NIC PLATE E10035 12 ENCODER SET 95142 13 CONDENSATOR 15 mf 800AC 70456 14 CABLE DUCT exterior 70388 15 ELECTRIC MOTOR 800 95130 16 PLASTIC CASING 70384 17 COVER FIXING SET LEFT RIGHT 95143 18 MICRO LIMIT SWITCH SET 95125 19 MICRO UNBLOCKING SET 95126 20 SPROCKET PROTECTION COVER 70395 21 OUTPUT COG M4 Z16 70380 22 UNBLOCKING LEVER SET MED 95140 23 UNBLOCKING LEVER MED 70455 24 LOCK WITH SET OF KEY...