background image

05 Main Menu (Page 4)

 

 

 

Switch Off Device

 

In addition to the Auto-Power-Off function, the user can turn off the device manually. 

It’s  recommended that the user turn off the device (or to wait for auto-power-off) 

before replacing the battery in order to save statistic counters. Otherwise the  changes 

since the last power up will be lost.

 

To turn off the device go to this menu item, wait until the display shows “0” then 

press the button.

 

 

 

Extended Functions Menu

 

The Extended Functions Menu has three sub-menus:

 

Heater Menu 

Settings related to the heater or coil

 

Mod Menu 

Settings related to the individual usage and appearance 

Value Menu 

Provides several statistics of vaping

 

The Extended Functions Menu offers many options to accommodate even the most 

discerning user. Once the user preferences are set, they rarely need to be changed. 

The more advanced settings were placed in the extended functions menu.  

The many options may frighten some of the users initially. But without the extended 

functions menu the mod would not be able to address all different customer 

requirements. Please take a bit of time to get familiar with the menu. We are sure, as 

soon as you have gained an overview, setting your preferences will be relatively 

easy.

 

 

 

Error Messages

 

If an error occurs, the mod directly jumps to the error menu and displays the error 

number and a mnemonic (short-term) description.

 

The possible error messages are:

 

0 OvrVolt:  The input voltage is too high. The dicodes 2380 designed for the use of one or two batteries.

 

If one battery is selected in the Extended Functions Stack Mode menu (Value=1) and the input 

voltage exceeds 4.5V “OvrVolt” will be displayed. With two batteries selected  (value=2), the error 

occurs for an input voltage >8.6V. Reduce the input voltage to the specified range. With stack 

mode set to “0” (automatic detection) the error is displayed for voltages >8.6V.

 

1

 

ChkAtom:  No atomizer detected or open coil.

 

2

 

TempRef:   A problem during the temperature reference measurement occurred

 

3

 

HighR: 

 The resistance of the coil is too high for the selected output power. The maximum output voltage 

is 12V and current is 15A. This specification together with a maximum output power of 80W 

leads to a resistance range of 0.4-1.7 Ohms. Also see “8 LowR”. Higher and lower resistances

 

are possible, but the power has to be reduced accordingly.

 

Example 1: With a 4Ohm coil the maximum power is (12V)²/4 Ohm=36W. 

Example 2: With a 0.12Ohm coil the maximum power is (15A)²*0.12 Ohm= 27W.

 

NOTE: The 12V and 15A maximums will limit the usable resistance  range.

 

4

 

OverCur:  Short on coil or coil breakdown (open)

 

5

 

LowBat:  The battery voltage under load (with current drained from it) has reached the minimum discharge 

level defined in UbatMin (in the Extended Function menu). The Ubatmin range  depends on the 

number of batteries used.

 

6

 

EleHot:  The electronics have overheated and need to cool down. This  error will not occur with  normal 

usage of the mod.

 

7

 

TimeOut:  The maximum puff-time is limited depending on power. For a power <20W it is 20 seconds. Above 

20W it decreases by 0.5 seconds per Watt, down to 10 seconds. Above 40W it stays at 10 

seconds.

 

8

 

LowR: 

The coil resistance is too low for the selected power, please see “3 HighR”.

 

Commented [SC6]: 

HOW? 

Commented [SC7]: 

How? 

Summary of Contents for 2380

Page 1: ...2380 2380T manual ...

Page 2: ...ns a with different length tube pieces to have one 18350 or 18500 or 18650 battery or two stacked batteries of 2x 18350 or 2x 18500 2x 18650 is possible by using an optional extension tube b as a telescope version dicodes 2380T with additional tube pieces 5 to 40W with one Li Ion battery 5 to 80W with two Li Ion batteries Adjustable battery discharge level 2 5 3V and 6 2 6 8V Up to 12V output volt...

Page 3: ...not displayed in Bypass Mode 2 with low no current Ub0 and high current load UbL Power Up Power Down 1 1 Heater Menu Temp Coefficient Down Power Limit Heater Protection Setting Power Boost Setting Mod Menu Display Luminosity Switch Off Time Power On Clicks Menu On Clicks Click Speed Half Wattage Temperature Unit C F Value Menu Vaping Time Energy Joule Wes Battery Capacitance Reset Counters Total L...

Page 4: ... Re set to Defaults ...

Page 5: ...rform a Manual Coil Temperature Calibration TempCal Init see next item Manual Coil Temperature Calibration This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below The Temperature calibration measures the coil resistance at room temperature 20 C as the reference for temperature controlled vaping The calibration must be confirmed by pressing t...

Page 6: ...ce of 4 Ohms and a power setting of 40W the required voltage at the coil would be 12 7V but given the 12V limit he maximum wattage is 36W 12V 4R 36W Or if the coil resistance is 0 1 Ohm the maximum power is 22 5W because 15A 0 1 Ohm 22 5W With high coil resistance the power is limited by the maximum voltage 12V and with low resistances the power is limited by the maximum current 15A These limits a...

Page 7: ...ost because the average power is increased by the boosts and the temperature cycles through significantly higher ranges Wert Power Boost Boostzeit ms Zeit auf Nennleistung ms Effektive Leistung bei 5W Nennleistung 1 2 3 4 5 6 7 8 9 10 300 450 600 50 80 120 160 200 250 300 500 600 700 800 900 1000 1000 Start Boost Start Boost Start Boost 6 18 6 53 6 9 7 17 7 36 7 6 8 0 Note If the power setting equ...

Page 8: ...f one battery is selected in the Extended Functions Stack Mode menu Value 1 and the input voltage exceeds 4 5V OvrVolt will be displayed With two batteries selected value 2 the error occurs for an input voltage 8 6V Reduce the input voltage to the specified range With stack mode set to 0 automatic detection the error is displayed for voltages 8 6V 1 ChkAtom No atomizer detected or open coil 2 Temp...

Page 9: ...attery quality Reset the counters above Total lifetime puffs of mod Not resettable Total lifetime vaping time of mod in HHHH MM Not resettable Enablesautomatic temperature calibration when set to 1 3 Select number of batteries 0 automatic 1 single 2 dual battery Select display orientationbetween Left and Right handed Select Expert mode to enable power boost heater protection and bypass mode Switch...

Page 10: ...pecify a minimum discharge level of 2 5V to 2 7V Since the voltage of a fully charged battery can quickly drop to 3 7V the protect your device the minimum power level allowed with two batteries installed is 6 2V If the user is unsure of the minimum discharge level of their battery the level should be set to 2 7V when using one battery or 6 4V when using two batteries The selected voltage is the vo...

Page 11: ...one or two batteries In Stack Control Stack Ctrl the user can select automatic detection 0 of the numbers of batteries or manually select one or two batteries The number of batteries inserted is determined through a measurement of total voltage Manually setting 1 or 2 adds a safety margin for the system since it s a user might insert two discharged batteries both at 2 2V so the total voltage is 4 ...

Page 12: ...declared by the manufacturer or if a battery is worn out This counter can be reset to 0 With stacked batteries the value shows the average capacity of the two TotCycl Total Cycles is the number of puffs throughout the entire mod s life It cannot be reset TotTime Total Time is the total time of vaping not stand by in a format HHHH MM that is 4 digits for hours and 2 for minutes It cannot be reset T...

Page 13: ...en persons allergic to nicotine or propylene glycol or persons with cardiovascular disease Selling electronic cigarettes to persons under 18 years of age is prohibited Battery Disposal Li Ion batteries may not be disposed in household waste Customers are required by law to dispose of worn out batteries at appropriate collection sites Mod Disposal The symbol below indicates that this device should ...

Reviews: