background image

06 Extended Functions Menu

 

Additional Explanation to several menu items, page 1

 

 

 

The following explanations are for a few items which are not self  explanatory or which have inter-

dependencies with other parameters or functions.

 

 

The selection of the correct wire-temperature-coefficient is very important for 

Temperature Controlled Vaping.

 

NOTE: that the coefficient of stainless steel can vary depending on alloy 

composition, manufacturer and production lot. For Titanium the coefficient values 

also vary significantly.

 

The TempCof item is present, even if the operation mode is not set  to Temperature 

Controlled Vaping.

 

 

 

The Power Limit has an effect on several functions of the mod:

 

-

 

Power Limit defines the range of the power selectable in the main menu. As stated 

before in the main menu, the limit value sets the roll-over point of the “Power Up” 

and “Power Down.” The power limitation makes sense especially in the  standard 

vaping mode as it helps prevent coil breaks when using small atomizers and small 

coils. 

 

-

 

Power Limit sets the power during the boost-phase in Power Boost mode.

 

 

 

 

All dicodes devices allow the user to set the minimum discharge level of the battery 

between 2.5V and 3.0V (single battery, older models up to 3.5V). On the 2380 with 

the use of two batteries, the discharge level can be set between 6.2 to 6.8V. Almost 

all batteries specify a minimum discharge level of 2.5V to 2.7V. Since the voltage of a 

fully charged battery can quickly drop to 3.7V, the protect your device the minimum 

power level allowed with two batteries installed is 6.2V. If the user is unsure of the 

minimum discharge level of their battery the level should be set to 2.7V when using 

one battery or 6.4V when using two batteries.

 

The “selected voltage” is the voltage at the poles of the battery when current is 

drained  from it (the current drained depends on the power at the coil). In contrast to 

other  tube and box mods on the market—which stop operation at 3.4V

 

(or 7.0V)—the lower discharge level on dicodes mods lead to better battery utilization 

(about 20% better).

 

 

 

 

The “time to automatic power off” of the mod can be set from 1 minute to 60 minutes. 

For best battery use we recommend selecting 2 or 5 minutes in conjunction with 

immediate  vaping enabled (”OnClick”=0). With this  combination, if the button is 

accidentally pressed AND held, it’s possible that the mod will exceed the maximum 

vape time (error 7), the device will auto power off, then immediately turn on and so 

forth in an endless loop.

 

To prevent this scenario, the mod has a built in safety feature: If “OnClicks”<2  

AND

 

Error 7 (TimeOut) happens 

AND

 the mod has gone through an auto-power-off, the 

mod can only be  switched on by clicking the button 5 times. 

 

As indicated, the OnClick range is from 0 (immediate vape) to 5. Note that the mod 

is always on after the first click, and if the selected number of clicks is not made, 

the device shuts itself off. 

 

Summary of Contents for 2380

Page 1: ...2380 2380T manual ...

Page 2: ...ns a with different length tube pieces to have one 18350 or 18500 or 18650 battery or two stacked batteries of 2x 18350 or 2x 18500 2x 18650 is possible by using an optional extension tube b as a telescope version dicodes 2380T with additional tube pieces 5 to 40W with one Li Ion battery 5 to 80W with two Li Ion batteries Adjustable battery discharge level 2 5 3V and 6 2 6 8V Up to 12V output volt...

Page 3: ...not displayed in Bypass Mode 2 with low no current Ub0 and high current load UbL Power Up Power Down 1 1 Heater Menu Temp Coefficient Down Power Limit Heater Protection Setting Power Boost Setting Mod Menu Display Luminosity Switch Off Time Power On Clicks Menu On Clicks Click Speed Half Wattage Temperature Unit C F Value Menu Vaping Time Energy Joule Wes Battery Capacitance Reset Counters Total L...

Page 4: ... Re set to Defaults ...

Page 5: ...rform a Manual Coil Temperature Calibration TempCal Init see next item Manual Coil Temperature Calibration This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below The Temperature calibration measures the coil resistance at room temperature 20 C as the reference for temperature controlled vaping The calibration must be confirmed by pressing t...

Page 6: ...ce of 4 Ohms and a power setting of 40W the required voltage at the coil would be 12 7V but given the 12V limit he maximum wattage is 36W 12V 4R 36W Or if the coil resistance is 0 1 Ohm the maximum power is 22 5W because 15A 0 1 Ohm 22 5W With high coil resistance the power is limited by the maximum voltage 12V and with low resistances the power is limited by the maximum current 15A These limits a...

Page 7: ...ost because the average power is increased by the boosts and the temperature cycles through significantly higher ranges Wert Power Boost Boostzeit ms Zeit auf Nennleistung ms Effektive Leistung bei 5W Nennleistung 1 2 3 4 5 6 7 8 9 10 300 450 600 50 80 120 160 200 250 300 500 600 700 800 900 1000 1000 Start Boost Start Boost Start Boost 6 18 6 53 6 9 7 17 7 36 7 6 8 0 Note If the power setting equ...

Page 8: ...f one battery is selected in the Extended Functions Stack Mode menu Value 1 and the input voltage exceeds 4 5V OvrVolt will be displayed With two batteries selected value 2 the error occurs for an input voltage 8 6V Reduce the input voltage to the specified range With stack mode set to 0 automatic detection the error is displayed for voltages 8 6V 1 ChkAtom No atomizer detected or open coil 2 Temp...

Page 9: ...attery quality Reset the counters above Total lifetime puffs of mod Not resettable Total lifetime vaping time of mod in HHHH MM Not resettable Enablesautomatic temperature calibration when set to 1 3 Select number of batteries 0 automatic 1 single 2 dual battery Select display orientationbetween Left and Right handed Select Expert mode to enable power boost heater protection and bypass mode Switch...

Page 10: ...pecify a minimum discharge level of 2 5V to 2 7V Since the voltage of a fully charged battery can quickly drop to 3 7V the protect your device the minimum power level allowed with two batteries installed is 6 2V If the user is unsure of the minimum discharge level of their battery the level should be set to 2 7V when using one battery or 6 4V when using two batteries The selected voltage is the vo...

Page 11: ...one or two batteries In Stack Control Stack Ctrl the user can select automatic detection 0 of the numbers of batteries or manually select one or two batteries The number of batteries inserted is determined through a measurement of total voltage Manually setting 1 or 2 adds a safety margin for the system since it s a user might insert two discharged batteries both at 2 2V so the total voltage is 4 ...

Page 12: ...declared by the manufacturer or if a battery is worn out This counter can be reset to 0 With stacked batteries the value shows the average capacity of the two TotCycl Total Cycles is the number of puffs throughout the entire mod s life It cannot be reset TotTime Total Time is the total time of vaping not stand by in a format HHHH MM that is 4 digits for hours and 2 for minutes It cannot be reset T...

Page 13: ...en persons allergic to nicotine or propylene glycol or persons with cardiovascular disease Selling electronic cigarettes to persons under 18 years of age is prohibited Battery Disposal Li Ion batteries may not be disposed in household waste Customers are required by law to dispose of worn out batteries at appropriate collection sites Mod Disposal The symbol below indicates that this device should ...

Reviews: