background image

USER´S MANUAL

 

7

 

4.2. CONFIGURATION PROGRAMMING 

 

 

This  enables  the  operation  of  the  scales  to  be 
personalised. 

 

go into programming and select configuration (0) 
The key functions are as follows: 

 

Key 

Function 

 

Back to initial programming status 

 

Set datum to zero 

 

Increase figure programmed 

 

Decrease figure programmed 

 

Record datum and move on to next 

 

The parameters programmed are: 
 

4.2.1 

AUTOMATIC DISCONNECTION 

 

This  programmes  whether  or  not  the  scales  is  to 
disconnect  automatically  if  a  set  time  elapses  with  no 
weight  being  placed  on  the  platform  and  no  key  being 
touched (only models with batteries). 
 
Numbers from 0 to 99 can be programmed. 
 
0 disables the automatic disconnection function, and any 
other  number  represents  the  minutes  which  will  elapse 
from  the  last  operation  to  disconnection.  To  re-connect 
the scales, press the on button. 
Press       to record and move on to the next parameter. 
 
 

4.2.2. 

EURO CONVERSION 

 

This window is for informative purposes only. 
Press 

 to go to the next parameter. 

 

 

 

4.2.3. 

SHOW EURO 

 

This  allows  you  to  select  whether  to  display  amounts  in 
your national currency only or also in euros. The settings 
permitted are 0 and 1 as follows: 
 
 

0

 -do not show amount in euros. 

 

1

 -show amount in national currency and in euros 

 

 

 

0 7 9 0 1

 

Summary of Contents for G300 Series

Page 1: ...G300 SERIES USER S MANUAL Ref 49BG300EN10...

Page 2: ...ATING THE SCALES 4 3 1 NORMAL WEIGHING 4 3 2 SET PRICE 4 3 3 TARE 4 3 4 SEGMENT TEST 5 3 5 AUTOMATIC ZERO 5 3 6 SHOW AMOUNT IN EUROS 5 3 7 SWITCHING ON OFF OF THE BACKGROUND LIGHT 5 4 PROGRAMMING 5 4...

Page 3: ...SCRIPTION OF THE SERIE G SCALE 1 1 KEYBOARD Setting button communication connector on bottom Numeric Keyboard LCD Plate Battery indicator Stable weight indicator On Off Key Level indicator Direct keyb...

Page 4: ...range minus one step 5 Choice of different operating modes 6 Amount calculated 7 RS 232 communications 2 3 INSTALLING THE SCALES 1 Use only adaptors and batteries supplied by DIBAL S A the use of any...

Page 5: ...a ventilated room When the battery needs to be charged an icon will light up on the display Recharge the battery as soon as the arrow appears over the symbol The scales will still work for about 10 h...

Page 6: ...2 Enter the price per kg by any of the following methods Directly from the numerical keys By typing in the item code and pressing By pressing the direct plu key from 1 to 18 Resets to zero to correct...

Page 7: ...and amount in euros The weight must be stable for the conversion to euros to work 3 7 SWITCHING ON OFF OF THE BACKGROUND LIGHT Use keys and to programme the display background light using the followi...

Page 8: ...ta that can be programmed for each item are 4 1 1 CODE Enter a number between 1 and 100 Press to go on to program the price or to record and move on to the next item 4 1 2 PRICE Numbers between 0 and...

Page 9: ...g placed on the platform and no key being touched only models with batteries Numbers from 0 to 99 can be programmed 0 disables the automatic disconnection function and any other number represents the...

Page 10: ...echnical assistance centre 4 3 PROGRAMMING OF GRAMS WINDOW To programme this parameter enter programming mode and press This parameter permits programming of a grams window in the weight display i e i...

Page 11: ...can the QR code or click on the link below to view the declaration of conformity http www dibal com DeclaracionesConformidad The information in this manual may be modified by the manufacturer without...

Page 12: ......