8.

 

System Installation 

Step 1:

 

Open package to check all 

components inside: Reactor Chamber, 
UV Lamp, Quartz Tube, O-ring, 
Electronic Ballast and Support.

 

     

 

Step 2:

 Make sure the Quartz Tube and UV 

Lamp are clean before installation (clean 
with alcohol or mild detergent). Wear soft 
non-abrasive gloves to keep any finger marks 
away from them.

 

 

Step 3:

 

Remove End Nut from 

Reactor Chamber.

 

 

 

Step 4:

 

Install O-ring onto the open 

end of Quartz Tube (12mm from the 
edge).

 

 

 

Step 5:

 

Insert the Quartz Tube into the 

Reactor Chamber.

 

 

Step 6:

 

Hand-screw End Nut on 

the Reactor Chamber. To protect 
the O-ring, do not over tighten.

 

 

 

Step 7:

 

Connect 4-pin Electrical 

Socket with UV Lamp pins tightly.

 

 

Step 8:

 

Carefully insert the UV Lamp into 

the Quartz Tube through End Nut.

 

                

 

Step 9:

 

Install the Cover Cap and 

hand-tighten onto End Nut.

 

 

 

Step 10:

 

Select a readily accessible 

and well lit location to fix the system. 
The system should always be located 
closest to the point of use and can 
either be installed horizontally or 
vertically.

 

Step 11:

 

When all plumbing connections are finished, slowly turn on the water 

supply and check for leaks.

 

Step 12:

 

Allow the water to run for a few minutes to clear any air or dust that may 

be in the Reactor Chamber.

 

Step 13:

 

Connect the power for starting up.

 

 

 

 

1 Reactor Chamber (304SS) 
2 Quartz Tube  
3 O-ring 
4 Open End Nut  
5 UV Lamp  
6 4-pin Electrical Socket 
7 Cover Cap 

8 Electronic Ballast 

9 Fitting 1/4° 

10 Support 

Summary of Contents for SSE-006

Page 1: ...ons The assumption is made that before making an attempt to operate the device the operator is familiar with the operation of the water sterilizer and has read its Operator s Manual Importer DiaSysTechnologies 1682 rue de la Valsiere 34790 GRABELS FRANCE FieldService ContactyourlocalDiaSysDiagnosticrepresentativeforsupport DiaSys Technologies DiaSys Diagnostic Systems are registered trademarks of ...

Page 2: ...to power c Do not proceed to install the equipment when UV Lamp or Sleeve Tube is broken buy one again and continue d Ultraviolet Disinfection System is designed for continuous operation and frequent switching will reduce Ultraviolet radiation and service life But if you do not use the equipment for a long time you can turn off the power and water supply to save energy e If this unit falls into th...

Page 3: ...t size 1 4 female thread Voltage 220 240V 50 60Hz Lamp power 6w Max working pressure 8 bar Ambient water temperature 2 40 Visual audible lamp alarm YES Visual power on YES Lamp replacement reminder NO Lamp working life reminder NO UV LAMP Power 6w Diameter 15mm T5 type Installation available length 212mm Current 0 425A Voltage 20V uvc intensity 254nm 22uW cm2 Working life 8 000 hours 7 Content of ...

Page 4: ...ctor Chamber To protect the O ring do not over tighten Step 7 Connect 4 pin Electrical Socket with UV Lamp pins tightly Step 8 Carefully insert the UV Lamp into the Quartz Tube through End Nut Step 9 Install the Cover Cap and hand tighten onto End Nut Step 10 Select a readily accessible and well lit location to fix the system The system should always be located closest to the point of use and can ...

Reviews: