006 UV Water Sterilizer operator’s manual
SSE-006 UV
water sterilizer Operator’s Manual
version 04.07.19
Page
2
/
4
2.
Safety
First of all, take care of your skin and your eyes from UV light !!! Never look directly at the light tube
while device is in operation. Do not remove the UV Lamp from the Reactor Chamber when
applying electrical power. Wear SAFETY GOGLES if you need to look necessary.
Basic safety precaution should always be followed to reduce the risk of fire, electric shock. Make
sure the leakage protection switch is installed before use.
Do not touch the UV Lamp directly in case of burning. A pair of gloves would be better when taking
off it.
3.
Precautions to do before using the device
a.
Water Quality Guidelines
The Ultraviolet Disinfection System is intended for the use with visually clear water, not colored, cloudy or
turbid
•
Ambient Water Temperature : 2-45°C
•
Iron : < 0.3ppm (0.3mg/L)
•
Hardness : < 7gpg (120mg/L)
•
Turbidity : < INTU
•
Manganese : 0.05ppm (0.05mg/L)
•
UV Transmittance : > 75%
b.
Recheck the installation before plus the sterilizer into power.
c.
Do not proceed to install the equipment when UV Lamp or Sleeve Tube is broken, buy one again and
continue.
d.
Ultraviolet Disinfection System is designed for continuous operation and frequent switching will reduce
Ultraviolet radiation and service life. But, if you do not use the equipment for a long time, you can turn
off the power and water supply to save energy.
e.
If this unit falls into the water, turn main power off and then retrieve it. Do not attempt to use this
sterilizer if it has been submerged.
f.
Do not operate this unit if it has damaged cord or plug, if it is malfunctioning or if it has been dropped or
been damaged in any manner
g.
The UV system should be installed after the filter on the return line
h.
Always disconnect the water supply and completely drain the water purifier if it will be subjected to
temperatures below freezing for extended periods of time.
4.
Maintenance
a.
Testing monthly or before each use
b.
Lamp replacement is recommended every 8000 hours of operation. After 8000 hours, the lamp may still
light, but the UV intensity has diminished.
c.
Cleaning of the quartz sleeve once 3-6 months with alcohol or a mild detergent.
5.
Spare parts
6W UV Lamp reference : 959001
SS006 UV lamp sterilizer: 959000