Electrical connecting 

 
The cabinet operates on 230 V/50 Hz. 
 
The wall socket should be easily accessible.  
 
All earthing requirements stipulated by the local electricity authorities must be observed. The 
cabinet plug and wall socket should then give correct earthing. If in doubt, contact your local 
supplier or authorized electrician. 
 
The flexible cord fitted to this appliance has three cores for use with a 3-pin 13-Amp or 3-pin 15-
Amp plug. If a B.S. 1363 (13-Amp) fused plug is used, it should be fitted with a 13-Amp fuse. 
 
The wires in this mains lead are coloured in accordance with the following code: 
Green/Yellow: Earth,  Blue: Neutral,  Brown: Live. 
 
The main electrical connections must be done by skilled electricians. 
 

Start-up of the cabinet 

 
Before use, we recommend that the cabinet is cleaned, see the section on maintenance and cleaning. 
 

Important ! 

If the cabinet has been vertically placed during transport, please wait 2 hours before starting up the 
cabinet. 
Connect the cabinet to a socket and turn on the switch on the control panel, see fig. 1.9. 
 

Fig. 1.9 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SB2/BD

Page 1: ...Mod SB2 BD Production code SA910BT 09 2010 ...

Page 2: ...direct sunlight 6 Always keep in mind that all electrical devices are sources of potential danger 7 Do not store inflammable material such as thinner gasoline etc in the cabinet 8 We declare that no asbestos nor any CFC are used in the construction 9 The oil in the compressor does not contain PCB Unpacking and installation Remove the wooden pallet and the packing External surfaces are supplied wit...

Page 3: ...in 15 Amp plug If a B S 1363 13 Amp fused plug is used it should be fitted with a 13 Amp fuse The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live The main electrical connections must be done by skilled electricians Start up of the cabinet Before use we recommend that the cabinet is cleaned see the section on maintenance and cle...

Page 4: ...ower the set temperature Press this key to save the new settings The display will flash with the new value and will then return to normal reading Alarm codes PF1 Flashing in the display indicates that the cabinet sensor is defective The cabinet will strive to keep the set temperature until it has been repaired Defrosting The cabinet defrosts automatically with pre set intervals If the door to the ...

Page 5: ...pressor compartment with water as this can cause short circuits and damage on the electrical parts Service The cooling system is a hermetically sealed system and does not require supervision only cleaning If the cabinet fails to cool check if the reason is a power cut If you cannot locate the reason to the failure of the cabinet please contact your supplier Please inform model and serial number of...