VI CLEANING AND MAINTENANCE 
 

      -     Clean the appliance regularly each time you use it.              
      -     For cleaning, use only mild on-abrasive maintenance products for stainless steel, 
            soapy water or dishwashing liquid with a non-abrasive sponge. 

-     Wipe the appliance with a damp cloth. 
-     Dry the appliance with a soft clean cloth. 

      -     Never clean the appliance with a jet of water because leaks could cause irreparable  
             damage to it. 
      -      Mind the capacity of the drip tray: it should be regularly emptied. Overflowings    
             in the appliance could generate irreparable damage. 
  
For a better service, we recommend you a periodic maintenance by qualified technicians. 
 
Your appliance can operate on liquid petroleum gas. To change one gas in another one 
requires the intervention of a qualified technician. 
 
 
 

VII DIMENSIONS AND CAPACITY 

 

 

 

Appliance 

Dimensions 

Cooking aera 

Weight 

PSR 400 GE 

400x475x230 mm 

400x400 mm 

17 Kgs 

PSR 600 GE 

600x475x230 mm 

600x400 mm 

27 Kgs 

PSR 900 GE 

900x475x230 mm 

900x400 mm 

37 Kgs 

 

Technical data 

 
 

Appliance 

Power 

Number of 

burners 

PSR 400 GE 

3.2 Kw 

PSR 600 GE 

6,4 Kw 

PSR 900 GE 

9.6 Kw 

 
 
 
 
 
 
 

 

Summary of Contents for FTG-40/SS

Page 1: ...Mod FTG 40 SS Production code PSR 400 GE 05 2010 ...

Page 2: ... s effectue par l intermédiaire de brûleur en étoiles garantissant une répartition uniforme de la chaleur Allumage Appuyez pendant quelques secondes sur le robinet Appuyez sur le piezo pour allumer le brûleur Maintenez le robinet appuyé pendant encore plusieurs secondes Le brûleur reste alors allumé réglez alors l appareil à la puissance désirée Un thermocouple coupe l alimentation en gaz en cas d...

Page 3: ...atégorie de gaz selon le pays de destination de l appareil Pays de destination Catégorie Gaz Pressions Diamètre d injecteur France Luxembourg II2E 3 II2E 3B P G20 G25 G30 G31 G20 G25 G30 G31 20 25 28 30 37 20 25 50 135 90 135 85 Allemagne II2E3B P G20 G25 G30 G31 20 20 50 135 150 85 Autriche II2H3B P G20 G30 G31 20 50 135 85 Belgique I3 I2E G30 G31 G20 G25 28 30 37 20 25 90 135 Suède Danemark Finl...

Page 4: ...ents à l intérieur de l appareil pourraient occasionner des dommages irréparables Pour un meilleur service nous vous conseillons un entretien périodique à faire effectuer par un installateur qualifié Votre appareil peut fonctionner avec les gaz de pétrole liquéfiés ou au gaz naturel Pour effectuer l adaptation d un gaz à l autre il est nécessaire d avoir recours à un installateur qualifié VII DIME...

Page 5: ...us temperature Lighting Press the knob in for a few seconds Press the piezo to light on the burner Keep the knob pressed in for a few more seconds The burner remains lit and now you can adjust the appliance to the setting required A thermocouple cuts off the gas supply if one of the burners goes out The appliance has a factory adjusted low flame setting This appliance is fitted with a completely r...

Page 6: ...able of gas categories according to country of destination of the appliance Country of destination Category Gas Pressures Diameter of injector France Luxembourg II2E 3 II2E 3B P G20 G25 G30 G31 G20 G25 G30 G31 20 25 28 30 37 20 25 50 135 90 135 85 Germany II2E3B P G20 G25 G30 G31 20 20 50 135 150 85 Austria II2H3B P G20 G30 G31 20 50 135 85 Belgium I3 I2E G30 G31 G20 G25 28 30 37 20 25 90 135 Swed...

Page 7: ...ay it should be regularly emptied Overflowings in the appliance could generate irreparable damage For a better service we recommend you a periodic maintenance by qualified technicians Your appliance can operate on liquid petroleum gas To change one gas in another one requires the intervention of a qualified technician VII DIMENSIONS AND CAPACITY Appliance Dimensions Cooking aera Weight PSR 400 GE ...

Reviews: