Diamond 503.004.201 Installation - Use - Maintenance Download Page 6

 

13 

  Do  not  obstruct  any  air  vents  or  drains  present  on 

the appliance.  

  Do not tamper with appliance components.  
 

 

 

4.

 

REFERENCE STANDARDS AND LAWS  

 

 

  Install  the  appliance  in  accordance  with  the  safety 

standards in force in the country.  

 

 

 

5.

 

UNPACKING 

 

 

  Check  the state  of the  packing  and  in  the  event  of 

damage,  ask  the  delivery  person  to  inspect  the 
goods.  

  Remove the packing.  
  Remove  the  protective  film  from  the  outer  panels. 

Use  a  suitable  solvent  to  remove  any  residual 
adhesive from the panels.  

 

 

 

 

 

6.

 

POSITIONING  

 

 

  The  overall  dimensions  of  the  appliance  and  the 

position of connections are given on the installation 
diagram at the start of this manual.  

  The  appliance  is  not  suitable  for  integrated 

installation.  

  Position the appliance at least 10 cm from adjacent 

walls. This distance can be reduced in the presence 
of non-combustible walls or heat-insulated walls.  

  The  appliance  has  no  moving  parts  which  could 

affect  the  stability,  therefore,  are  not  provided  for 
locking elements to the ground.  

 

 

 

7.

 

CONNECTIONS 

 

 

  The  position  and  dimensions  of  connections  are 

given  in  the  installation  diagram  at  the  end  of  this 
manual.  

 

 

 

CONNECTION TO THE WATER SUPPLY 

 

 

  The  appliance  must  be  connected  to  a  potable 

water supply (max 35°C. ). The water inlet pressure 
must  be  between  1,  5  -  3  bar.  Use  a  pressure 
reducer if the inlet pressure is above the maximum 
permitted level.  

  Install  a  mechanical  filter  and  a  shut-off  valve 

upstream  of  the  appliance  in  an  easily  accessible 
point.  

  It  is  necessary  to  have  a  supply  of  drinking  water 

with hardness<10 °F to avoid circuit blockage.  

 

 

  Make  sure  the  water  circuit  is  free  of  ferrous 

particles  before  connecting  the  filter  and  the 
appliance.  

  Seal any unused connectors with a plug.  
  Once the appliance has been installed, check for gas 

leaks at the connection points.  

 

 

 

 

INSTALLATION OF A WATER SOFTENER IS 
RECOMMENDED TO AVOID LIMESTONE 
DEPOSIT.  

 

 

 

WATER DISCHARGE 

 

 

  Water discharge is located in the lower part of the 

oven  and  is  to  be  connected  to  a  rigid  pipe,  the 
diameter  of  which  should  fit  the  discharge 
connection.  

  The down flow pipe must be fitted at least 20 cm, 

underneath the attachment.  

  Any discharge blockage can be the cause of any bad 

odours  in  the  baking  chamber  or  of  any  steam 
coming out of the door.  

 

 

 

ELECTRICAL CONNECTIONS 

 

 

  Check  that  the  appliance  is  designed  to  operate  at 

the  voltage  and  frequency  of  the  power  supply 
present  on  site.  Check  the  details  given  on  the 
appliance dataplate.  

 

 

  Install  upstream  of  the  equipment  in  an  easily 

accessible  place,  an  all-pole  disconnecting  device 
with  a  contact  gap  of  allowing  full  disconnection 
under the conditions of overvoltage category III.  

  A flexible rubber cable with insulation specifications 

not  lower  than  type  H05  RN-F  must  be  used  for 
connection.  

  Connect  the  power  supply  cable  to  the  terminal 

board as shown in the wiring diagram supplied with 
the appliance.  

  Secure  the  power  supply  cable  with  the  cable 

clamp.  

  Protect  the  power  supply  cable  on  the  outside  of 

the appliance with a rigid plastic or metal pipe.  

 

 

Summary of Contents for 503.004.201

Page 1: ...Mod BRIO43 X N Production code 503 004 201 05 2015 ...

Page 2: ...C FAN OVENS Installation Use Maintenance MOD BRIO43 X N BRIO 43S X N BRIO64 X N CPE434 N CPE643F N CPE644 N CPE 644 N 230 1 CPE664 NP GASTRO23 X N CGE23 N CGE11 N CGE11 N 230 1 CGE611 NP Doc n 252 386 00 Edition 07 ...

Page 3: ... 15 11 REMINDERS FOR CLEANING 15 V INSTRUCTIONS FOR MAINTENANCE 15 12 REMINDERS FOR THE MAINTENANCE TECHNICIAN 15 13 REPLACING COMPONENTS 15 14 MAIN COMPONENTS 16 PANNELLO DI CONTROLLO CONTROL PANELS PANNEAU DE CONTROLE SCHALTBRETT PANEL DE CONTROL TAB1 DATI TECNICI TECHNICAL DATA TECHNISCHE DATEN CARACTERISTIQUES TECHNIQUES DATOS TECNICOS TECHNISCHE GEGEVENS DATI TECNICI APPARECCHIATURE ELETTRICH...

Page 4: ... operating DO NOT STORE AMMABLE MATERIALS IN CLOSE PROXIMITY TO THE APPLIANCE FIRE HAZARD Identify the specific appliance model The model number is detailed on the packing and on the appliance dataplate DO NOT OBSTRUCT ANY AIR VENTS OR DRAINS PRESENT ON THE APPLIANCE This device emits a sound pressure level less than 70 dB A In the event of an appliance fault or malfunction switch the appliance of...

Page 5: ...entally friendly materials The plastic recyclable components are the transparent cover the bags containing the instructions manual and nozzles made of Polyethylene PE the straps in Polypropylene PP APPLIANCE The appliance is manufactured 90 from recyclable metals stainless steel aluminium sheet copper The appliance must be scrapped in compliance with current regulations governing such disposal Mak...

Page 6: ...upstream of the appliance in an easily accessible point It is necessary to have a supply of drinking water with hardness 10 F to avoid circuit blockage Make sure the water circuit is free of ferrous particles before connecting the filter and the appliance Seal any unused connectors with a plug Once the appliance has been installed check for gas leaks at the connection points INSTALLATION OF A WATE...

Page 7: ...stance centres authorized by the manufacturer and demand the use of original spare parts The appliance is designed for professional use and must be operated by trained personnel This equipment is designed for cooking food It is intended for industrial use Any other use is to be considered improper The first time the appliance has to be used under no load conditions at the highest temperature to el...

Page 8: ...ergents that are suitable for oven cleaning do not use these for grills as they are too aggressive and rich in caustic soda The use of any unsuitable compound can cause oven component corrosion Do not clean the appliance with direct jets of water V INSTRUCTIONS FOR MAINTENANCE 12 REMINDERS FOR THE MAINTENANCE TECHNICIAN THE MANUFACTURER WILL NOT BE LIABLE FOR ANY DAMAGE OR INJURY RESULTING FROM FA...

Page 9: ...Refit all parts Following in reverse order the sequence used for their removal Replacing the working thermostat safety thermostat motor timer and spies Open the door Remove the wrap Remove the inner panel Remove and replace the component Refit all parts Following in reverse order the sequence used for their removal 14 MAIN COMPONENTS humidification push button signal light for grill grill timer ti...

Page 10: ...MER SIGNAL LIGHT TIMER LAMPE TIMER KONTROLL LÄMPCHEN TESTIGO TIMER INDICADOR LUMINOSO DO TEMPORIZADO S LAMPJE TIMER 5 TIMER GRILL GRILL TIMER TIMER GRILL TIMER GRILL TIMER GRILL TEMPORIZADO R DO GRELHADOR TIMER GRILL 6 SPIA GRILL SIGNAL LIGHT FOR GRILL GRILL LAMPE GRILL KONTROLL LÄMPCHEN TESTIGO GRILL INDICADOR LUMINOSO DO GRELHADOR LAMPJE GRILL 7 PULSANTE UMIDIFICAZION E HUMIDIFICATIO N PUSH BUTT...

Page 11: ...IMUM TOTAL TOTAL MAXIMUM MAXIMALE GESAMT TOTAL MÁXIMA MÁXIMA TOTAL SEZIONE CAVO ALIMENTAZIONE SECTION POWER CABLE CÂBLE D ALIMENTATION DE LA SECTION ABSCHNITT NETZKABEL CABLE DE ALIMENTACIÓN DE LA SECCIÓN CABO DE ALIMENTAÇÃO SEÇÃO V N Hz kW GASTRO23 X N 220 240 1 N 50 60 3 3 3 G 1 5 CGE23 N 220 240 1 N 50 60 3 5 3 G 1 5 CGE11 N 230 1 220 240 1 N 50 60 3 5 3 G 1 5 CGE11 N 220 240 3 50 60 6 3 4 G 4 ...

Reviews: