25
- Press
several times to:
Display the maximum residual chilling time remaining
Display the message “nEg”;
Display the flashing cabinet temperature;
Exit the procedure, or leave for 15 s.
If the temperature measured by the pin probe reaches the chilling endpoint temperature prior to expiry of
the maximum chilling time duration, the device will switch to storage mode and the display will show the
message “End”. The buzzer will sound for the period of time set by parameter AA. Press any key to mute the
buzzer, press once more to cancel the message “End”.
If the temperature measured by the pin probe does not reach the chilling endpoint temperature prior to
expiry of the maximum chilling time duration, chilling will continue, the LED will flash and the LED
will be on, the buzzer will sound, press
several times to:
- Mute the buzzer;
- Display the time elapsed since the maximum chilling time expired
- Display the cabinet temperature;
- Display the message “nEg”;
- Exit the procedure, or leave for 15 s
When the temperature measured by the pin probe reaches the chilling endpoint
temperature, the
device will switch to storage mode, the LED will continue to flash and the
LED will stay
on. The display will show the message “End”, the buzzer will sound for the period of
time
set
by
parameter AA, press any key to mute the buzzer, press once more to cancel the message “End”.
During storage:
The display shows the cabinet temperature. If chilling had a positive outcome, the LEDs and
will be on, If chilling had a negative outcome, the LEDs
will
be on and the LED
will flash , the parameter rA sets the operational set-point, Press several times to:
- Display the message “nEg”
- Exit the procedure, or leave for 15 s.
To interrupt the cycle, Press
for 2 s.
2.10
TEMPORARY SETTING OF OPERATIONAL SETPOINT DURING STORAGE
Ensure the device is in “stand-by” mode and no procedures are running
- Press
the LED will flash
- Press
or within15 s
- Press
or leave for 15 s.
The setting remains active until another operational cycle is selected, when the value assigned by parameter
r9 or ra is restored.
2.11
TO RE-START USING THE SAME SETTINGS AS THE LAST CYCLE RUN
Ensure that the device is in “stand-by” mode, that no procedures are running and that another cycle has not
been selected.
Press
2 s: the display will show the label of the last cycle run.
- Press
within 60 s, in the case of a timed cycle, the display will show the duration of the blast
chilling
step (in minutes) or in the case of a set-temperature cycle, the set target temperature
- Press
or within 15 s to change the value (the setting remains active until another cycle is
selected, when the value r1, r2, r3 or r4 is restored)
- Press
within 15 s: the cycle will be activated