background image

PRECISION 2000 DELUXE ASSEMBLY INSTRUCTIONS

A. Reservoir Installation

1) Place reservoir on a 

 rm level surface, to prevent saw from tilting or rocking. The small compartment of the reservoir 

    should  be on the left side of the saw.

2) Lift saw and insert feet into the 4 openings in the reservoir base (Fig. 17). 

B.

Recirculating Water System

The durable recirculating water pump and reservoir tray collects and recycles water.

1) Remove water bottle and tubing from the saw and set aside. 

2) Place the PRECISION 2000™ with the reservoir on a solid level work surface, 

 at-side facing forward.

3) Insert pump valve into the top of the recirculating water pump. Place pump in the left rear compartment of the 

    reservoir (Fig.18). Press down on the pump to activate the suction cups, securing pump to the bottom of the reservoir.

4) Connect the plastic tubing to the top of the pump. Note: Running the plastic tubing under warm water will make 

    it easier to insert into the stem. Next, connect the opposite end into the top of the brass water nozzle on the upper 

    guide assembly (Fig.19). Plug pump’s electrical connector into an outlet or power strip.

5) Fill the reservoir with approximately 2” of water (Approximately 3 quarts) before use.

6) To test pump, the saw must be turned on. Be sure the blade has been properly installed and there are no 

    obstructions that may interfere with its operation and blade movement. DO NOT attempt to touch the blade or 

    blade wheels while the machine is turned on.

7) Test pump and water 

 ow by turning machine on at a slow speed. Water should begin to 

 ow freely from the water 

    nozzle mounted on the upper blade guide assembly. If necessary, adjust position of nozzle so water 

 ow is directed 

    at the front of the blade (See Fig.8).

8) If large pockets of air appear in the hose line, this may stop the 

 ow of water to the blade. If this should occur, 

    turn the saw off. Remove the hose from the pump nozzle without removing the pump from the water and let the 

    hose drain. Reattach the hose and start the saw again. Small air bubbles may persist in the line, but these will not 

    interfere with suf

 cient 

 ow to the blade.

WARNING: Never operate saw if there is insuf

 cient water at the point of cutting, as this will cause damage to the blade.

Fig.15

Fig.16

Fig.18

Fig.19

Fig.17

Summary of Contents for Studio Pro Precision 2000

Page 1: ......

Page 2: ...the blade Always hold material being cut rmly against cutting table Feed materials at a slow easy pace into the blade Avoid sudden twisting of the blade which may cause kinking or breaking Never leave...

Page 3: ...w backwards and loosen screw located underneath the lower cover Rotate plastic tab away from the base of the cover Fig 2 and slide cover off 3 With the upper and lower blade wheels exposed place a han...

Page 4: ...and upper blade guides Correct alignment of these guides is essential to proper glass cutting and extending blade life 1 The blade should pass through the grooves of the upper and lower blade guides w...

Page 5: ...ed with the position turn locking knob to secure alignment in place Return the water bottle and wheel covers to their normal operating positions Fig 14 Fig 13 5 If the blade is riding too far backward...

Page 6: ...upper guide assembly Fig 19 Plug pump s electrical connector into an outlet or power strip 5 Fill the reservoir with approximately 2 of water Approximately 3 quarts before use 6 To test pump the saw...

Page 7: ...e blade which may affect performance Additionally scratches in the surface of the blade will ll with pitch making it more dif cult to clean the next time To clean blades soak with oven cleaner 8 Shoul...

Page 8: ...returned at the owner s expense Diamond Tech reserves the right to repair or replace faulty equipment at its discretion The Precision 2000 Band Saw is warranted against defective materials or workman...

Reviews: