Ziggy User Manual Rev 1.0
Page 14
6.1.3
Camera (J3)
30pin I-PEX connector is used to directly plug the camera modules.
1
3.3V
2
3.3V
3
3.3V
4
5V-
5
NC
6
NC
7
NC
8
NC
9
PWR#
10
NC
11
NC
12
NC
13
NC
14
FLASH
15
MCLK
16
RST#
17
SDA
18
SCL
19
NC
20
DATA2-
21
DATA2+
22
DATA0-
23
DATA0+
24
CLK-
25
CLK+
26
GND
27
DATA1-
28
DATA1+
29
DATA3-
30
DATA3+
Connector:
20525-030E-02C.
Mating Cable: FAW-1233-03 (Pinouts are reversed in cable)
Camera supported: LI-IMX274-MIPI-CS and LI-IMX185-MIPI-CS