Grounding IMG1010 (DC Version Only)
The DC version of the IMG 1010 should be connected to a true earth ground. To connect chassis
to ground you will need the following equipment:
14-16 AWG machine tool wire (MTW) (green/yellow)
# 10 solder-less crimp connector with two-hole mounting option to connect to grounding
lug. (Dialogic-supplied).
Procedure
1.
Remove the two-hole grounding lug at the rear of the IMG 1010 by removing the grounding
screws.
2.
Crimp the grounding wire to the lug. Re-attach the lug to the unit using the grounding
screws.
3.
Attach the other end of grounding wire to either a grounding point on the mounting rack or a
building ground point.
For more information on connecting IMG 1010 to ground see
IMG 1010-Installation and
Setup Guide > IMG 1010-Hardware Installation
in Online Documentation.
Configuring Linux on GCEMS server
IMPORTANT:
Please read and understand the IMG 1010 technical documentation prior to
performing any setup or installation procedures. The documentation can be accessed
through the following site:
http://www.dialogic.com/manuals
If the IMG 1010 was purchased with the GCEMS Server then the Linux Red Hat Operating
System and GCEMS application have already been installed. Downloading System Software
to the IMG 1010 will be the next step. See paths below in online documentation.
IMG 1010-Installation and Setup Guide > IMG 1010-Software Installation and Setup
If server was not purchased, then a server must be configured with Red Hat Enterprise
Linux. The IMG 1010 supports Red Hat Enterprise Linux 3, Red Hat Enterprise Linux 4 and
Red Hat Enterprise Linux 5. Refer to the individual topics located under each of the following
headings in the Online Documentation for more information on configuring the Linux Server.
IMG 1010-Installation and Setup Guide > IMG 1010-Linux Red Hat Installation
IMG 1010-Installation and Setup Guide > IMG 1010-Software Installation and Setup
IMG 1010-Installation and Setup Guide > IMG 1010-SD Card
Configuring Services on GCEMS Server