Specifications 

Nominal AC Supply Voltage 

 

 

100-277VAC, 50-60Hz 

Power consumption: 

2’ 

version 

   50W 

nominal 

4’ 

version 

   100W 

nominal 

Operating temperature range 

 

 

-40°F to +149°F [-40°C to +65°C] 
T5 @ 149°F [65°C] 

Power 

factor 

    >0.9 

ATHD 

      

<20% 

 

Dimensions (L x W x H)  

 

 

See Figure 5. 

Weight   

 

 

 

 

17 lbs [7.71 kg] (4’), 12 lbs [5.44 kg] (2’) 

Intertek Certified to 

 

 

 

UL-844 and C22.2 No. 137 

Figure 5. 

 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for SAFESITE LSD3C4M2P

Page 1: ...INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No 9100 127 1452 00 Rev B May 2011 MODELS LSD3C4M2P LSD3C4D2P Downloaded from Arrow com ...

Page 2: ...65 C CLASS II DIV 2 GROUPS F G pending Outdoor Type Wet Locations Ta Ambient Temp 40 TO 65 C Temp Rating T5 2 ft T5 4ft Note Save these instructions for future reference 2 Installation Warning To avoid the risk of fire explosion or electric shock this product should be installed inspected and maintained by a qualified electrician only in accordance with all applicable electrical codes To avoid ele...

Page 3: ...Use conductive pipe sealant for all fittings and conduit o Fixture is factory wired for both Pendant and Through wiring Remove the Power Supply Covers to attach incoming power to the white wire and black wire leads with wire nuts at the end of the fixture Attach the ground wire to the green ground lead supplied at the end of the fixture Repeat this procedure for the opposite end Ensure that the o ...

Page 4: ...pply Housing in order to be assembled to conduit o Attach conduit as shown in figure 3 Use conductive pipe sealant for all fittings and conduit o Fixture is factory wired for both Pendant and Through wiring Remove the Power Supply Covers to attach incoming power to the white wire and black wire leads with wire nuts at the center of the fixture Attach the ground wire to the green ground lead suppli...

Page 5: ... is recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B Recommended Practice for Electrical Equipment 2 The lens Figure 4 should be cleaned periodically as needed to ensure continued photometric performance Clean the lens with a damp non abrasive lint free cloth If not sufficient use mild soap and water 3 Inspect the outside of the luminaire housing to ensur...

Page 6: ...ersion 50W nominal 4 version 100W nominal Operating temperature range 40 F to 149 F 40 C to 65 C T5 149 F 65 C Power factor 0 9 ATHD 20 Dimensions L x W x H See Figure 5 Weight 17 lbs 7 71 kg 4 12 lbs 5 44 kg 2 Intertek Certified to UL 844 and C22 2 No 137 Figure 5 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Down...

Page 7: ...anteed In accordance with Dialight Corporation Terms and Conditions of Sale and since conditions of use are outside our control the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith REV ECO No DRN CHK APP QA CM DATE A 2992 WSL GZ SB RL JB 1 28 11 B 3735 WSL SB KZ RL JB 5 16 11 Downloaded from Arrow c...