Reliant High Bay Replacement Power Supplies
WARNING: Any replacement power supply must be a DIRECT REPLACEMENT for the existing power supply.
-
No changes in lumen output or AC voltage input permitted.
1.
Open the access cover on the luminaire by loosening the captive screw. If the luminaire is equipped with a center mounted occupancy sensor,
remove the sensor lens by rotating the lens ¼ turn counterclockwise. Then undo the snap features and slide the cover open.
2.
Cut zip tie and disconnect plugs (shown below).
3.
Remove 2x 8-32 SEMS screws that hold the power supply to the luminaire (shown below
4.
Slide the power supply forward out of the rear mounting tabs and lift the supply out of the luminaire and discard according to respective
national regulations on waste disposal.
WARNING: To avoid fire and
electrical shock, turn off power at
circuit breaker or fuse and test
that the power is off before wiring.
Cut and remove
Zip Tie
Unplug
Connector
Unplug
Connector