Document No: 9100-127-1835-99 Rev C
Page 4 of 5
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
3: Maintenance
Warning:
EXPLOSION HAZARD. Do not disconnect equipment unless power has been switched off or the
area is known to be non-hazardous.
Avertissement:
RISQUE D'EXPLOSION. Avant de deconnecter l'equipement, couper le courant ou
s’assurer que l’emplacement est designe non dangereux.
Warning:
No user serviceable parts inside of fixture. Consult the manufacturer.
Disconnect power to the light and allow the unit to cool down before performing maintenance.
Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine checks to
be made on a yearly basis. Frequency of use and environment should determine this. It is recommended to
follow an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommended Practice
for Electrical Equipment.
The lens should be cleaned periodically as needed to ensure continued photometric performance. Clean the
lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid cleaner. Do not use
an abrasive, strong alkaline or acid cleaner as damage may occur.
Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or contamination
(i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.